- Insert the water drain hoses in the plastic tray.
- Fit the front covers to complete the cabinet (7) (8) (9).
Self-bearing Top Structure - Installed (Fig. 6C)
- Unscrew the wooden tables placed under the cabinet (1).
- Lift the cabinet and place it in its final position (2).
- Remove the transport sheets (3).
- Then level the structure throughout its length and depth.
- Fix the structure to the wall (4) or to the floor (5) as shown earlier in section 5. (RECOMMENDED)
- Insert the water drain hoses in the plastic tray.
- Fit the front covers to complete the cabinet (6) (7) (8).
6 - Electrical connections
Important: installation should be made following the manufacturer's instructions, by qualified personnel only, in conformity
with the electric safety regulations in force. Please refer to the electrical diagram on FIG.14-15.
At the input of the supply it is necessary to install an omni-polar magnetothermic/differential device with contact opening
equal to 3 mm and adequate cut-off power.
Warning: Before connecting the unit to the mains, make sure that the mains voltage corresponds to that indicated on the
serial plate (bearing in mind that the max acceptable variations in voltage are +/-10%). Check that the cable used has the
right cross-section and length to withstand the current and the power absorbed by the combination, as indicated in TAB.1.
The plug-in units are supplied already fitted with a 2,5 m cable and plug (see FIG. 7), so the unit must not be installed
more than 2,5 m from the nearest wall socket. The cabinet should be connected to its own fixed current socket (i.e.
without extension leads or multiple plugs).
The cable should be fully extended, protected from accidental hits and located where it can not be caught or trod upon. It
must be away from water and other liquids and heat sources and must not be damaged. In case of breakage of the power
cable of the cabinet, it must be replaced by the manufacturer or by institution in charge of it. The plug must still be
accessible even after installing the unit.
Warning: Follow the Manufacturer's instructions to install the unit, using qualified personnel and in compliance with the
electrical regulations for the specific country (electrical safety standards and laws, accident and fire prevention laws, EC
directives). Incorrect installation may cause injury and damage. The Manufacturer cannot be held liable for this.
The unit must be earthed. The Manufacturer cannot be held liable for any damage or injury should this safety regulation
be ignored. If the unit is to be installed far from the electrical sockets, suitable electrical connections are needed and
these must comply with the prevailing standards. The use of adapter plugs is strictly prohibited. The Manufacturer
cannot be held liable for any damage or injury arising from incorrect installation.
7 - Technical details
The display unit is accompanied by a plastic envelope containing this instruction manual. This manual must be kept with
the machine. It contains all the technical data, wiring diagrams and tables needed for the unit.
The following technical data are also shown on the serial plate (FIG. 8):
1. Name and address of the manufacturer
2. Commercial name of the cabinet
3. Cabinet code
4. Cabinet serial number
5. Rating
6. Frequency
7. Max absorbed current
8. Max absorbed power
9. Max absorbed power during defrosting
10. Standard lighting power
11. Net display area
12. Type of cooling gas used
13. Weight of cooling gas loaded in each unit
14. Climate class and reference temperature (dry bulb)
15. Electrical safety factor
16. Work schedule number
17. Work order number
18. Year of manufacture
19. Heating capacity
20. QR code
21. EAC marking
Warning: The serial plate and the warning labels must never be removed from the unit. The Manufacturer cannot be held
liable for any damage or injury if this warning is ignored.
The Manufacturer states that this unit complies with Italian legislative degree n° 108 dated 25.01.1992, implementing