– Position the end of the condensation drain hose above a wa-
ter drain. For larger distances, a longer hose of the same
type can also be used.
– The device can also be operated with a condensation pump.
®
Contact TROTEC
customer service if you want this alterna-
tive version.
3. Ensure that the condensation drain hose always descends.
16x1 mm
EN
Switching on the device
1. Ensure that the condensation drain hose (5) has been laid and
connected properly. Do not create tripping hazards.
2. Ensure that the condensation drain hose (5) is not bent or
jammed and that there are no objects on the condensation
drain hose (5).
3. Ensure that the condensation can run off properly.
4. Insert the mains plug into a properly secured mains power
socket. Do not create tripping hazards.
5. Empty any condensation from the device by pressing the but-
ton for draining residual water from the condensation pump
(optional).
6. Ensure that the device is standing stably in its working posi-
tion.
7. Switch on the device at the mains switch (9).
"Continuous" operation mode
In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity in the air.
"Humidistat" operation mode (optional)
The device can also be operated with a humidistat.
The humidistat switches the device on or off depending on the
humidity.
If you choose to operate the device with an optional humidistat, set
the desired humidity at the humidistat (see operating manual of
the optional humidistat).
Automatic defrost
Depending on the air temperature and the relative humidity, the
evaporator fins may become covered in frost. The hot gas auto-
matic defrost which is installed in the device switches back on as
needed. Dehumidify mode is briefly interrupted during defrosting.
Operating Manual – Construction dryer TTK 800