Technical data
Parameters
Model
Dehumidifying capacity, max.
Dehumidifying capacity (20 °C / 60 % relative humidity)
Suitable for room dimensions up to:
construction drying or clearing water damages
maintaining dryness
Operating temperature
Working range for relative humidity
Volume of airflow, max.
Electric connection
Power consumption, max.
Power consumption, average
Fuse (home)
Compressor
Refrigerant
Amount of refrigerant
Weight
Dimensions (HxDxW)
Minimum distance from walls of other objects
Sound pressure level LpA (3 m; complies with DIN 45635-01-KL3)
Power consumption
The device's power consumption depends on the current room
temperature and relative humidity.
Multiply the operating hours (see operating hours counter in the
chapter "Operating elements") by a consumption value of one
kilowatt per hour to determine the approximate power consump-
tion.
To determine the precise power consumption, a separate energy
cost gauge can be set between the construction dryer and the
power source. Contact TROTEC
alternative version.
B - 3
®
customer service if you want this
Operating Manual – Construction dryer TTK 800
Values
TTK 800
150 l / 24 h
55 l / 24 h
800 m³
1600 m³
0-40 °C
35-100 %
940 m³/h
230 V / 50 Hz / 9.5 A
2.4 kW
1.7 kW
16 A
Rotary
R407c
1.05 kg
70 kg
1020 x 585 x 630 mm
A: Above: 50 cm
B: Behind: 50 cm
C: Side: 50 cm
D: Front: 50 cm
60 dB(A)
EN