The control panel is made-up of three LED, a 7 segment display and a button:
POWER LED, CHARGE PHASE LED (BULK, ABSORPTION, FLOAT) ERROR LED, STATUS display and ON/
STAND-BY button (see fig.4).
FIG.4
ON/STAND-BY BUTTON:
Use this button to put the battery charger in stand-by mode. To activate this mode simply press the button
quickly (press and release in less than one second). To take the battery charger out of stand-by mode,
press the button quickly again or disconnect the battery charger from the AC power supply and then
connect it up again.
The information supplied by the LEDS are listed as below:
POWER LED
LED COLOUR
DESCRIPTION
OFF
No mains power
Green
Power ON
Flashing
Battery charger in stand-by mode
CHARGE PHASE LED
LED COLOUR
LED STATUS
OFF
-
Red
Fixed
Orange
Fixed
Green
Fixed
Red
Flashing
Orange
Flashing
Green
Flashing
ERROR LED
LED COLOUR
DESCRIPTION
OFF
No problem with manual reset
Red
Problem with manual reset (see error codes)
26
(BULK, ABSORPTION, FLOAT)
DESCRIPTION
No output power
BULK phase - charge at constant current
ABSORPTION phase - charge at constant voltage
FLOAT phase - float charge
BULK phase - charge at constant current - digital control of the parallel units on
ABSORPTION phase - charge at constant voltage - digital control of the parallel units on
FLOAT phase - float charge - digital control of the parallel units on