WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
18. Plug in ice maker or reconnect power.
19. Turn on ice maker.
20. Wait for rinsing cycle, approximately 5 minutes, to be sure the
ice maker is operating properly.
Drain Connection
Gravity Drain System
Connect the ice maker drain to your drain in accordance with all
state and local codes and ordinances. If the ice maker is provided
with a gravity drain system, follow these guidelines when
installing drain lines. This will help keep water from flowing back
into the ice maker storage bin and potentially flowing onto the
floor, causing water damage.
Drain lines must have a minimum of 5/8" (15.88 mm) inside
■
diameter.
Drain lines must have a 1" drop per 48" (2.54 cm drop per
■
122 cm) of run or 1/4" drop per 12" (6.35 mm per 30.48 cm) of
run and must not have low points where water can settle.
The floor drains must be large enough to accommodate
■
drainage from all drains.
The ideal installation has a standpipe with a 1½" (3.81 cm) to
■
2" (5.08 cm) PVC drain reducer installed directly below the
outlet of the drain tube as shown. You must maintain a 1"
(2.54 cm) air gap between the drain hose and the standpipe.
Do not connect the outlet end of the drain tube to a closed
■
pipe system to keep drain water from backing up into the ice
maker.
IMPORTANT: A drain pump is necessary when a floor drain is not
available. A Drain Pump kit, Part Number 1901A, is available for
purchase.
Side View
1⁷⁄₈"
(4.8 cm)
23"
(58.4 cm)
(5 cm - 3.8 cm)
A. Drain hose
D. Center of drain should be 23" (58.4 cm
B. 1" (2.54 cm) air gap
from front of door, with or without the 3/4"
C. PVC drain reducer
(1.91 cm) panel on the door. The drain
should also be centered from left to right
(7
5
maker) unless installing with a spacer.
Drain Pump System (on some models)
Connect the ice maker drain to your drain in accordance with the
International Plumbing Code and any local codes and ordinances.
NOTES:
If the drain hose becomes twisted and water cannot drain,
■
your ice maker will not work.
Do not connect the outlet end of the drain tube to a closed
■
pipe system to keep drain water from backing up into the ice
maker.
Connecting the Drain
After ensuring that the drain system is adequate, follow these
steps to properly place the ice maker:
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Plug into a grounded 3 prong outlet.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
ice maker.
Failure to do so can result in back or other injury.
A
B
1" (2.54 cm)
C
D
2" - 1¹⁄₂"
⁄
" [18.56 cm] from either side of the ice
16
9