Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• If necessary shorten platic hose according to the
table and insert it up to the collar into the shorter blue
marked copper pipe.
• The drain valve must only be used as intended. It is not
allowed to attach other objects to the drain valve, for
example a semi-pedestal.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended operating pressure:
Rate of flow:
Thermal disinfection:
The product is exclusively designed for drinking water!
Highest possible water pressure at
user's site in Mpa
0,1 - 0,15
0,2 - 0,3
0,4 - 0,7
If the water pressure is greater than 0,5 MPa, fit a pressure reducing valve.
Fault
Insufficient water
Mixer stiff
Mixer dripping constantly with water
heater switched off
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 5 l/min
max. 70°C / 4 min
Table for the throttle hose lengths to be used
8, 10 and 15 liters
without throttle hose
Throttle hose shortened to 90 mm
Cause
- Spray former calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
Assembly (see page 31)
English
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 34)
Spare parts (see page 36)
When changing the spray former, it is
imperative to use one made for this type of
mixer.
Special accessories
(order as an extra)
special tool #58085000 (see page 32)
Installation putty (see page 32)
Operation (see page 35)
• Hansgrohe recommends not to use as
• When the storage tank is being heated,
Cleaning (see page 38)
Test certificate (see page 40)
Device content
Throttle hose unchanged
Adjust flow volume at corner valve
drinking water the first half liter of water
drawn in the morning or after a pro-
longed period of non-use.
the spout will drip.
up to 5 liters
Throttle hose shortened to 90 mm
Throttle hose unchanged
Remedy
- Clean spray former, exchanging if
necessary
- Exchange cartridge