After operation, remove dust from both sides of the blade
with wired brush, wipe off it with a rag and then apply
enough low-viscosity oil, such as machine oil etc. and
spray-type lubricating oil.
CAUTION:
• Do not wash the blades in water. Failure to do so may
cause rust or damage on the tool.
Storage
Put the blade cover on the shear blades so that the blades
are not exposed. Store the tool out of the reach of children
carefully.
Store the tool in the place not exposed to water and rain.
To maintain product SAFETY and RELIABILITY, repairs,
carbon brush inspection and replacement, any other
maintenance or adjustment should be performed by
DOLMAR Authorized Service Centers, always using
DOLMAR replacement parts.
ACCESSORIES
CAUTION:
• These accessories or attachments are recommended
for use with your DOLMAR tool specified in this
manual. The use of any other accessories or
attachments might present a risk of injury to persons.
Only use accessory or attachment for its stated
purpose.
If you need any assistance for more details regarding
these accessories, ask your local DOLMAR Service
Center.
• Extension cord
• Blade cover
• Hook complete
• Waist cord hook
• Arm cord hook
EC-DECLARATION OF CONFORMITY
The undersigned, as authorized by, declare that the
DOLMAR machines,
TYPE:
HT-42, HT-48, HT-52
complies with the standard safety and health
requirements of the pertinent EU guidelines:
EU machinery guideline 98/37/EC, Noise emission
2000/14/EC, EU EMC guideline 2004/108/EC.
The requirements of the above EU guidelines were
implemented chiefly on the basis of the following
standards: EN60745-2-15, EN 55014, EN61000. The
conformity assessment procedure 2000/14/EC was
performed per Annex V. The measured sound pressure
level (L
): is 82.1 dB (A). The measured sound power
pA
level (L
) is 93 dB (A). The guaranteed sound power
wa
level is 96 dB (A).
Vibration
The vibration total value (tri-axial vector sum) determined
according to EN60745-2-15:
Vibration emission (a
h, D
Uncertainty (K): 1.5 m/s
2
): 6.7 m/s
2
Tamiro Kishima
Managing Director
ENH020-1
Hamburg, CE2009
For DOLMAR GmbH
Rainer Bergfeld
Managing Director
9