Anleitung BT-AC 140-24 OF_SPK1:_
10. Possible causes of failure
Problem
The compressor does not start
1. No supply voltage
2. Insufficient supply voltage
3. Outside temperature is too low
4. Motor is overheated
The compressor starts but there is
1. Leak in the non-return valve
no pressure
(13)
2. The seals are damaged.
3. The drainage screw for
condensation water (14) leaks.
The compressor starts, pressure is
1. Loose hose connections
shown on the pressure gauge, but
the tools do not start.
2. Leak in a quick-lock coupling
3. Insufficient pressure set on the
pressure regulator.
05.11.2007
9:18 Uhr
Cause
Solution
1. Check the supply voltage, the
power plug and the
socket-outlet.
2. Make sure that the extension
cable is not too long. Use an
extension cable with large
enough wires.
3. Never operate with an outside
temperature of below +5°C.
4. Allow the motor to cool down. If
necessary, remedy the cause of
the overheating.
1. Replace the non-return valve
2. Check the seals and have any
damaged seals replaced by a
service center
3. Tighten the screw by hand.
Check the seal on the screw
and replace if necessary.
1. Check the compressed air hose
and tools and replace if
necessary.
2. Check the quick-lock coupling
and replace if necessary.
3. Open the pressure regulator
further.
Seite 15
GB
15