Télécharger Imprimer la page

ADEUNIS LoRaWAN Europe EU863 Guide Utilisateur page 54

Publicité

Les langues disponibles

Les langues disponibles

FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3
Example : 0018B244 41524632 0018B200 00000912
S216 = 0018B244
S217= 41524632
S218 = 0018B200
S219 = 00000912
S253 à S256 : Configuration Channel
FR
By default, the channels from 0 to 2 use the default parameters of the LoRaWAN network, while the 4 other channels are inactive. A range
value different from 0 or 1 will allow you to configure the channel as follows:
Bit
Description
Example
EN
Data Rate (DR) value
0
1
2
3
4
5
6
7
NOTE: the example given will allow you to configure a 868.1 Hz frequency and authorizes a SF from 7 to 9. The command to send in order to
carry out this operation is:
ATS250=86810053<cr>
S281: DEVICE ADDRESS
This range will allow you to determine the address of the device on the network when using the ABP mode. In the OTAA mode, this parameter
is automatically input during the JOIN phase.
7
6
5
Channel frequency
Description
SF12
SF11
SF10
SF9
SF8
SF7
SF7 - BW 250Khz
FSK 50 kbps
4
3
868100
2
1
0
DR Max
DR Min
5
3