Sommaire des Matières pour ADEUNIS LoRaWAN Europe EU863
Page 1
FIELD TEST DEVICE LoRaWAN Europe EU863-870 Guide utilisateur / User Guide Version V1.2.3 Adeunis 283 rue Louis Néel - Parc Technologique Pré Roux 38920 CROLLES - France www.adeunis.com...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Table des matières / Contents / ... FRANÇAIS INFORMATIONS DISCLAIMER SUPPORT TECHNIQUE INTRODUCTION RECOMMANDATIONS ENVIRONNEMENTALES AVERTISSEMENTS RECOMMANDATIONS D’USAGE PRÉSENTATION DU PRODUIT 1.1. Description 1.2. Caractéristiques mécaniques 1.3.
Page 3
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 ENGLISH INFORMATIONS DISCLAIMER TECHNICAL SUPPORT INTRODUCTION ENVIRONMENTAL RECOMMENDATIONS WARNINGS RECOMMENDATIONS REGARDING USE DISPOSAL OF WASTE BY USERS IN PRIVATE HOUSEHOLDS WITHIN THE EUROPEAN UNION INTRODUCING THE DEVICE 1.1.
Page 6
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Déclaration UE de Conformité Nous adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Déclarons que la DoC est délivrée sous notre seule responsabilité et fait partie du produit suivant : Modèle produit :...
ADEUNIS se réserve le droit de modifier les spécifications techniques ou des fonctions de ses produits, ou de cesser la fabrication de l’un de ses produits, ou d’interrompre le support technique de l’un de ses produits, sans aucune notification écrite et demande expresse de ses clients, et de s’assurer que les informations à...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 RECOMMANDATIONS ENVIRONNEMENTALES Tous les matériaux d’emballage superflus ont été supprimés. Nous avons fait notre possible afin que l’emballage soit facilement séparable en trois types de matériaux : carton (boîte), polystyrène expansible (matériel tampon) et polyéthylène (sachets, feuille de protection en mousse). Votre appareil est composé...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 RECOMMANDATIONS D’USAGE • Avant d’utiliser le système, vérifiez si la tension d’alimentation figurant dans son manuel d’utilisation correspond à votre source. Dans la négative, consultez votre fournisseur. •...
1.1. Description Le Field Test Device (FTD) d’Adeunis est un produit compatible LoRaWAN V1.0 Class A. Ce n’est pas un produit point à point et il ne peut pas être utilisé dans ce sens. Cela signifie qu’il doit être utilisé sur un réseau opéré privé ou public.
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 1.3. Spécifications techniques Radio Communication LoRaWAN protocol & LoRa Modulation Compatibilité Spécification LoRaWAN V1.0.1 Débit Radio Variable (SF12/125kHz (~183 bps) to FSK (~50kbps) Puissance RF 14dBm (25mW) Sensibilité...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 3. DESCRIPTION DES ECRANS L’écran LCD du produit est divisé en plusieurs écrans : • L’écran de DÉMARRAGE (Affichage des versions de firmware) - Uniquement à la mise sous tension •...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Les requêtes sont identifiées «JR» suivi d’un numéro indiquant le nombre de requête effectuées. Cette information est suivi de la fréquence d’émission à laquelle la requête est réalisée. Note : Si aucun réseau n’est disponible, les «Join Request»...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 3.4. Ecran GPS Cet écran est accessible par un appui court sur le bouton poussoir 2 après le menu principal. Il permet de visualiser les informations de fonction- nement du module GPS, ainsi que le positionnement GPS du produit.
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 L’écran affiche : • Le nombre de trames envoyées (UL COUNT), y compris les répétitions • Le nombre de trames reçues (DL COUNT) • Le Packet Error Rate (PER) en pourcentage La mesure du PER est réalisée en comparant le nombre de trames émises par rapport au nombre de trames reçues : •...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 4.2. Température Binaire N° Octet Commentaires Valeur 0001 Température en °C (Complément à 2) -128 ... +127 1011 Aide au décodage de la température Bit de signe Bit 6 Bit 5 Bit 4...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 4.5. Qualité GPS (Non disponible en mode legacy) Valeur N° Commentaires Valeur 1 : Bonne 7..4 Échelle de réception 2 : Moyenne 3 : Mauvaise 3..0 Nombre de satellites 1 ...
Vous devez voir apparaître lors de la connexion un périphérique série USB avec un numéro de port COM associé. Si vous ne voyez aucun périphérique de ce type, vous devez installer le driver USB pour ce périphérique, disponible sur notre site internet : https://www.adeunis.com/en/produit/ftd-868-915-2/ Sélectionnez : •...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 5.2. Mode commande Utiliser un terminal port COM pour communiquer avec le produit. Nous utilisons le soft terminal port COM HERCULES disponible en téléchargement gratuit à l’adresse suivante : https://www.hw-group.com/products/hercules/index_en.html •...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 • Envoyer la trame de passage en mode commande pour basculer le produit en mode de configuration, en cliquant sur le bouton SEND. Après quelques secondes, vous devez voir apparaître sur le LCD du produit l’écran COMMAND MODE. Cela peut prendre un peu de temps car le passage en mode commande ne peut être réalisé...
Page 22
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Exemple d’une suite de commandes et de réponses correspondantes telles qu’on pourrait le voir sur un terminal : Syntaxe de la Commande Description Syntaxe de la réponse à la ligne suivante Demande d’entrée en mode commande ATS221=1 Demande de passage en mode d’activation...
Page 23
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Valeur par Registre Contenu Commentaires défaut 0 : Désactivé S385 Payload personnalisée 1 à 16 : Taille de la payload personnalisé S386 Payload personnalisée - Bloc 1 S387 Payload personnalisée - Bloc 2 Chaque bloc permet de définir 4 octets de la payload...
Page 24
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 S382 : Mode ACK et Class Le registre permet de choisir le mode de fonctionnement du produit : • Mode Unconfirmed • Mode Confirmed S383 : Uplink Port Le port de communication de la trame d’Uplink peut être configuré...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Valeur par Registre Contenu Commentaires défaut S250 Configuration Canal 0 Canaux de fonctionnement obligatoire LoRaWAN S251 Configuration Canal 1 Cette valeur ne doit pas être modifiée. S252 Configuration Canal 2 Configuration Canal 3...
Page 27
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Exemple : 0018B244 41524632 S214 = 0018B244 S215 = 41524632 S216 à S219 : LORA APP_KEY Les registres S216 à S219 définissent la clé APP_EKY utilisée lors de la phase de JOIN en mode OTAA. La clé est composée de 32 caractères repartis sur ces 4 registres pouvant contenir chacun 8 caractères.
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 S253 à S256 : Configuration Canal Par défaut, les canaux 0 à 2 utilisent les paramètres par défaut du réseau LoRaWAN, les 4 autres canaux sont inactifs. Une valeur du registre différente de 0 ou 1 permet de configurer le canal comme suit : Description Fréquence du canal...
Les références des versions chargées dans le produit peuvent être connues avec la commande AT/S Exemple : APP_8123AAB_PRG_1801_V01.01.02:RTU_8134AAE_PRG_1701_V01.04.00 La version firmware APPLICATIF est : V01.01.02 La version firmware RTU est : V01.04.00 Une procédure complète est disponible sur la page produit de notre site internet : www.adeunis.com 7. HISTORIQUE DU DOCUMENT Version Contenu V1.0.0 Création...
RTU : V01.02.00 DISCLAIMER This document and the use of any information contained therein, is subject to the acceptance of the adeunis terms and conditions. They can be downloaded from www.adeunis.com. adeunis makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice.
Page 32
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 EU Declaration of Conformity adeunis 283 rue LOUIS NEEL 38920 Crolles, France 04.76.92.01.62 www.adeunis.com Declare that the DoC is issued under our sole responsibility and belongs to the following product:...
Under no circumstances can the manufacturer, or the distributor of an Adeunis program, be held liable for any damage caused by the use of the aforesaid program. Program names, as well as all copyright relating to programs, are the exclusive property of Adeunis.
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 ENVIRONMENTAL RECOMMENDATIONS All superfluous packaging materials have been eliminated. We have done everything possible to make it easy to separate the packaging into three types of materials: cardboard (box), expanded polystyrene (filler material) and polyethylene (packets, foam protective sheets). Your device is composed of materials that can be recycled and reused if it is dismantled by a specialist company.
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 RECOMMENDATIONS REGARDING USE • Before using the system, check that the power supply voltage shown in the user manual corresponds to your supply. If it doesn’t, please consult your supplier.
1.1. Description The Field Test Device (FTD) from Adeunis is a Class A LoRaWAN compatible device. This is not a point to point device and may not be used in this manner. This indicates that it must be used on a private or public operated network.
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 1.3. Technical specifications Radio Communication LoRaWAN protocol & LoRa Modulation LoRaWan Specification compliant V1.0.1 Radio Rate Variable (SF12/125kHz (~183 bps) to FSK (~50kbps) RF Power 14dBm (25mW) Sensitivity down to -140 dBm in SF12/CR4 Range (Open)
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 3. SCREEN DESCRIPTION The LCD screen of the product is split on few part : • The START screen (Showing the firmware version) - Only on the powering up •...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 The request are identify «JR» following with a number showing the number of request done. The frequency used for the request is showing after this information. Note : If there is no network available, the «Join Request»...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 3.4. GPS screen This screen can be accessed by briefly pressing on pushbutton 2 after the home screen. It will allow you to view the functioning information of the GPS module, as well as the device’s GPS positioning.
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 The screen will display: • The number of frames sent (UL COUNT), including repetitions • The number of frames received (DL COUNT) • The Packet Error Rate (PER) as a percentage The PER measurement is calculated by comparing the number of frames transmitted to the number of frames received: •...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 4.2. Temperature Binary N° Bit N° Comments 0001 Temperature in °C (two’s complement) -128 ... +127 1011 Aid for decoding temperature Sign Bit Bit 6 Bit 5 Bit 4 Bit 3 Bit 2...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 4.5. GPS quality (Not available in Legacy mode) Value N° Bit N° Comments Value 1: Good 7..4 Reception scale 2: Average 3: Poor 3..0 Number of satellites 1 ...
You should see the USB series device with a corresponding COM port number appear during connection. If you are not able to see a device of this type, you must install the USB driver for this device, available to download from our website: https://www.adeunis.com/en/produit/ftd-868-915-2/ Select: •...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 5.2. Command mode Use a COM port terminal in order to communicate with the device. We use the HERCULES COM port soft terminal available to download for free by clicking on the following link: https://www.hw-group.com/products/hercules/index_en.html •...
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 For Hercules, this frame must be entered in one of the 3 lines available at the bottom. The hexadecimal format must be expressed using a “$” in this program, which gives us the following frame: $FF$FF$FF$FF$FF$2B$2B$2B •...
Page 48
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Example of a set of commands and corresponding responses that can be seen on the terminal: Command syntax Description Response syntax \FF\FF\FF\FF+++ Input request in command mode ATS221=1 Transition request in OTAA activation mode E ->...
Page 49
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Range Content Default value Comments Personalize Payload Text - Bloc 1 S386 Personalize Payload Text- Bloc 2 S387 Each bloc allow to define 4 bytes of the payload Personalize Payload Text- Bloc 3 S388 S389...
Page 50
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 S382 : Class and ACK Mode The range will allow you to select the method of functioning for the device: • Unconfirmed Mode • Confirmed Mode S383 : Uplink Port The communication port for the Uplink frame can be configured in this frame.
Page 51
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Range Content Default value Comments S214 LORA APP_EUI (First section) 0018B244 Parameter coded with 16 characters. Each range contains a section of the key. S215 LORA APP_EUI (Second section) 41524632 S216 LORA APP_KEY (First section)
Page 52
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Range Content Default value Comments S250 Configuration Channel 0 Mandatory channels of the LoRaWAN specification. S251 Configuration Channel 1 These values cannot be modified. S252 Configuration Channel 2 Configuration Channel 3 S254 Configuration Channel 4...
Page 53
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 S216 to S219: LORA APP_KEY The ranges from S216 to S219 determine the APP_KEY used during the JOIN phase in OTAA mode. The key is made up of 32 characters spread across these 4 ranges, which can each contain 8 characters.
Page 54
FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3 Example : 0018B244 41524632 0018B200 00000912 S216 = 0018B244 S217= 41524632 S218 = 0018B200 S219 = 00000912 S253 à S256 : Configuration Channel By default, the channels from 0 to 2 use the default parameters of the LoRaWAN network, while the 4 other channels are inactive. A range value different from 0 or 1 will allow you to configure the channel as follows: Description Channel frequency...
It is possible to find out the references for versions loaded onto the device using the command AT/S Example : APP_8123AAB_PRG_1801_V01.01.02:RTU_8134AAE_PRG_1701_V01.04.00 The APP firmware version is: V01.01.02 The RTU firmware version is: V01.04.00 The full procedure is available on the device page of our website: www.adeunis.com 7. DOCUMENT HISTORY Version Content V1.0.0...