Télécharger Imprimer la page

ADEUNIS LoRaWAN Europe EU863 Guide Utilisateur page 48

Publicité

Les langues disponibles

Les langues disponibles

FIELD TEST DEVICE - LoRaWAN Europe - Guide utilisateur / User guide version V1.2.3
Example of a set of commands and corresponding responses that can be seen on the terminal:
Command syntax
\FF\FF\FF\FF+++
ATS221=1
ATS214=0018B200
FR
ATT63 PROVIDER
ATS214=0018B200
ATS215?
AT&W
ATO
EN
Interpreting the previous example: the user wanted to modify the start of the APP_EUI after having made an unauthorized command (answer
E), and the ranges were unblocked in order to modify the range. The second section of the APP_EUI was verified and the parameters were
saved before exiting. When exiting command mode, the device will make a JOIN request.
5.4. Register description
Once supplied with power, the Field Test Device will function according to the last saved configuration (factory settings if this is the first time
the device has been switched on, or if this configuration has not been changed).
ATS<n>=<m> or ATR type modification commands allow you to modify the content of these ranges.
It is essential to save the parameters using the AT&W command before exiting the command mode, otherwise all of your changes will be lost.
5.4.1 Function register
Below is a list of the ranges accessible on the device (by default). These ranges make it possible to modify the device's behavior.
Details on how each range functions can be found elsewhere in the table.
Range
S370
S371
S380
S382
S383
S385
Description
Input request in command mode
Transition request in OTAA activation mode
APP_EUI MSB modification change
Unblock the operating range
APP_EUI MSB modification change
Feeds back the value of the S215 range
Memory request for the state range
Output request in command mode
Content
Payload format
GPS configuration
Frame transmission period
ACK and Class mode
Uplink Port
Personalized Payload Size
Response syntax
CM
O
E -> This command is not validated (register no unlocked)
O
O
S200=44512451
O
O
Default value
0 : Format Legacy (Demonstrator)
0
1 : Format Field Test Device
0: GPS deactivated
1: GPS activated/Continuous Mode
11
11 : GPS activated/Continuous Mode + GPS Reset (Cold
Start)
0: No periodic transmission
600
1 to 86400 (expressed in seconds) : Periodic transmission
0: Class A Unconfirmed
1: Class A Confirmed
1
All other values will be retained.
1
1-223
0 : Deactivated
0
1 to 16 : Size of the payload
Comments
Page
48
of 55

Publicité