En Instructions For Use / Assembly Instructions - Hansgrohe AXOR Citterio 39210000 Mode D'emploi / Instructions De Montage

Masquer les pouces Voir aussi pour AXOR Citterio 39210000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pressu-
res.
Installation Instructions
The fitting must be installed, flushed and tested after
the valid norms.
If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart®
(flow limiter) located behind the aerator can be
removed.
Technical Data
This mixer series-produced with EcoSmart®
(flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
4
English
Symbol description
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max.. 80°C
65°C
Assembly see page 31
Do not use silicone containing acetic acid!
Dimensions (see page 34)
Flow diagram
(see page 34)
with EcoSmart®
without EcoSmart®
Operation (see page 33)
Cleaning
see enclosed brochure.
Spare parts (see page 35)
Special accessories
special tool (58085000) order as an extra
Installation kit order as an extra

Publicité

Table des Matières
loading

Table des Matières