Alarm 41 Product expiry time setting:
This command is activated when the number of hours set for the expiry of the product has elapsed, after
which the vending machine prohibits the sale of the product. The maximum settable time is 999 hours. If this
function is not required, program 00 for Alarm 41.
N.B. Set the clock before activating this option (see Alarm 02).
Alarm 46 Product expiry time selection setting:
This command makes it possible to set the selections which will be prohibited from sale, once the time set in
Alarm 41 has elapsed. To reset the timer simply enter the code "A0B" on the selection keyboard when the
door is open ("DOOR OPEN" appears on the display). Once the code A0B has been keyed in, "Reset Expiry
Time" appears on the display. At this point the vending machine will allow the sale of the products for the
amount of time set in Alarm 41.
Alarm 51 Weekly check daily inhibition vend point:
The command only functions if Alarms 01, 02 and 03 are set and the control is enabled, and concerns both
the master machine and any slaves connected to it. Up to 3 daily time slots can be set.
N.B.: The value 2400 set on "Start time slot 1" disables the function.