18
Once the installation procedure is terminated, open the door and hold down the "TEST" button on the main
board for approx. 3 sec., until a buzzer emits a prolonged sound. This indicates that you have entered
programming mode and the text "Comando 00" appears on the display.
E
N
G
L
I
S
H
To Enter a Command, press the corresponding command on the selection panel and press the button
ENTER to confirm the selection. Push-button ENTER is used also to confirm the inserted board-data and to
store them. In this case on the display appears for a few seconds the message "OK". To leave programming
mode or to pass from a submenu to the main menu press A.
Caution: if push button "TEST" is released before the required time the vending machine enters the "check
selection" mode described below. If so, exit this mode by pressing the push button "TEST" once again, then
repeat the operations required to access the programming mode.
Every time the door opens, the selections, if present, that are out of service or not in "home position" (having
executed a quarter turn) will appear on the display (see Command 76). The selections can be reset (by
rotating them) by pressing button "B". If the door is closed again without having reset all the selections, the
event is recorded as an error displayed in Command 99 with code number 91.
ATTENTION: Rotating the selection to reset it with the door open could cause the product to fall to
the ground.
N.B.: With SPIRALI SLAVE connection enabled (see command 49), after the MASTER machine display,
access is gained to the display of the same data relevant to the SLAVE machine by simply pressing the A
(ESC) button.
9.1
CHECK SELECTION
It is also possible to carry out a function test of the machine by pressing the pushbutton TEST placed on the
main card. The message "SELECTIONS OK" will appear on the display. As an alternative an indication (ex.
12, 14...) could appear to indicate that an irregularity has taken place during the functioning and the spirals
indicated are out of service. Carry out the selection shown on the display to reset. If a working mistake
happens during the test, the tag of the spiral will stay on the display; otherwise the test will go on to the next
out-of-work spiral. If all the selections are all right the corresponding message will appear on the display.
It is possible to test all the selections typing in the corresponding tag. After having finished the test press
again the push-button test on the main card to go back to normal working.
N.B.: To avoid errors the machine returns automatically to normal work after about 1 minute from the
access to test mode, during which no operation is carried out.
If during the test or the reset there should happen some errors, it means that the anomaly is not occasional
but could result from the breakage of some parts and a technical intervention is required.
9
PROGRAMMING PROCEDURE
MEGACOLD S/M – Issue 01