28
Command 76 System's operating options ("FTC Options "):
Setting this command determines how the machine will react if the product is not delivered. The value can be
set at between 0 and 2. Default = 0.
The meaning of the setting is as follows:
0 = Possibility of another selection; in this case command 63 (single-multisale) must be set at 1 (if it is an
executive payment system the multisale must also be set in the payment system).
1 = Automatic credit delivery; in this case command 63 must be set at 0 (if it is an executive payment system
the single sale must also be set in the payment system).
2 = Further quarter turn: if the product is not delivered the spiral completes a further 1/4 turn and if the
product has still not been delivered then the machine reverts to one of the preceding two options depending
on the single or multisale parameter that has been set.
•
For this purpose once the value 2 has been set in command 76, the option is disabled for all the
selections by default. Then you automatically access the menu that allows you to enable the option for
E
the individual spirals. To enable the option corresponding to a spiral simply enter the selection number
N
and set the value at 1. Vice versa if this value is set at 0 the option is disabled. The option is not
G
applicable to ½ turn spirals. If the payment system uses Executive protocol, the single-multivend must
L
also be set on the payment system.
I
•
Alternatively, the function can be enabled / disabled for each drawer: selection 91 implies that all the
S
selections in the first drawer from the top are, for example, enabled for the quarter turn function. Selection
H
92 = 2nd drawer; 93 = 3rd drawer; 94 = 4th drawer; 95 = 5th drawer; 96 = 6th drawer; 97 = 7th drawer; if
you program the function for selection 99, all the selections in the vending machine will be enabled or
disabled.
The system then asks you to enter the options relevant to the PHOTOCELL SAFETY:
enabling this function (parameter setting = 1) involves entering a number of products within a certain time
frame (in minutes). If within the programmed time interval a number of non-readings occurs that is equal to
the number of programmed products, the photocells are disabled. The active event is signalled on the display
when the door is opened and it is also recorded in Command 99 by Error code 39. The photocell reset can be
programmed in manual or automatic mode. If manual, parameter setting = 0, enter the TEST VEND function
to re-enable the photocells; if automatic, parameter setting = 1, after 15 minutes the system attempts to reset
the function.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
Command 80 Cloning:
This command makes it possible to transfer all the parameters of the vending machine to a "Program Key",
to program same model machines. When you enter the command "Write Clone Key" appears on the display.
Then, enter the "Program Key" and press the ENTER key. "Data Writing...*" appears on the screen while the
data is being transferred to the key. Once the data transfer operation is completed, the machine returns to
the programming mode.
Caution: DO NOT enter the key before entering the programming mode, otherwise the vending machine will
fetch the data existing in the key.
Command 81 Fetch vend data:
This command makes it possible to transfer all the EVA-DTS data to a "Program Key". This data can be
extracted using special software (VMC configurator). The maximum number of possible registrations is 100.
Attention: if the key is not recognised as a data key, at the first registration the user will be asked to confirm
the complete deletion of the existing data.
Command 85 Display of checksum and main and power board software version.