5- Wiring; Connect The Cable - Saunier Duval 2-035 AK Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48

5- WIRING

CAUTION!
The air conditioner should use separate power
supply with rated voltage.
The wiring work should be done by qualifi ed
persons according to circuit drawing.
An all-pole disconnection switch with a contact
separation of at least 3mm at each pole should
be connected in fi xed wiring.
Be sure to locate the power wiring and the
signal wiring well to avoid cross-disturbance.
Do not turn on the power until you have
checked carefully after wiring.
NOTE!
Remark per EMC Directive 89/336/EEC.
For to prevent fl icker impressions during the
start of the compressor (technical process),
following installation conditions do apply.

5.1- CONNECT THE CABLE

Dissemble the bolts from the cover.
1 The power connection for the air conditioner
has to be done at the main power distribution.
The distribution has to be of a low impedance,
normally the required impedance reaches at a
32 A fusing point.
2 No other equipment has to be connected with
this power line.
3 For detailed installation acceptance please
refer to your power supplier, if restrictions do
apply for products like washing machines, air
conditioners or electrical ovens.
4 For power details of the air conditioner refer to
the rating plate of the product.
5 For any question contact your local dealer.
Connect the connective cables to the terminals
as identifi ed with their respective mached
numbers on the terminal block of the unit.
Re-install the cover or the protection board.
14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2-050 ak2-075 ak

Table des Matières