TECHNICAL DATA
Definition in accordance with EN 13240
Constructive system
Global thermal power in kW
Nominal thermal power in kW
Power given back to water in kW
Power given back to the room in kW
Hourly wood consumption in kg / h (wood with 20% humidity)
Efficiency in %
CO measured at 13% oxygen in %
Smoke outlet diameter in mm
Chimney height - dimension in mm
Fluid contents of the exchanger in L (litres)
Chimney draught in Pa (mm H
Boiler connections (Ø)
Automatic discharge pipe diameter (Ø)
Outer air inlet Ø in mm (minimum surface cm
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Optimal working temperature in °C
Max. working pressure in bar
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances
heatable m
(30 kcal/h x m
3
(#) 200 mm diameter can be used with flue of no less than 6 m.
For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume
(# #)
of the product is: favourable type of building (30 kcal/h x m
of building (50 kcal/h x m
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary
heating, in the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
IMPORTANT: The power of the connected heating system must be proportional to the power transferred to the water by the
thermoproduct; a charge which is too low does not allow regular oven operation, while a charge which is too high prevents adequate
radiator heating.
The declared technical data have been achieved by burning beech wood class "A1" according to the requirement UNI EN ISO 17225-
5 and wood moisture content less than 20%. By burning a different kind of wood the efficiency of the product itself could change and
some specific adjustments on the appliance could be needed.
GENERAL PRECAUTIONS
La NORDICA S.p.A. responsibility is limited to the supply of the appliance.
The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.
Installation must only be carried out by a qualified technician who works on behalf of companies suitable to assume the entire
responsibility of the system as a whole.
La NORDICA S.p.A. declines any responsibility for the product that has been modified without written authorisation
as well as for the use of non-original spare parts. NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE.
La NORDICA S.p.A. cannot be held responsible for lack of respect for such precautions.
It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also
fireproof rules.
24
O)
2
)
2
)
3
).
3
TermoROSSELLA
TermoROSSELLA
Plus - DSA
Plus Forno - DSA
1
17.3
13.5
10.5
3
4
78.2
0.10
130
(#)
4m 250x250 Ø250 - 5m 220x220 Ø220
18.5
17-20 (1,7 / 2,0) 17-20 (1,7 / 2,0) 17-20 (1,7 / 2,0) 17-20 (1,7 / 2,0)
1 "F gas
½"M gas
200 (100 cm
)
200 (100 cm
2
13.5
270
70 - 75
VEA1,5 – VEC3
VEA1,5 – VEC3
355x245
307x245x345
307x318x345
-
330x300x370
915
559
533
160 - 175
(# #)
390
); less favourable type of building (40 kcal/h x m
3
ENgLIsH
TermoNICOLETTA
- DSA
1
1
16.6
17.3
13.5
13.5
10.5
10.5
3
3
3.9
4
81,1
78.2
0.07
0.10
130
130
18.5
18.5
1 "F gas
1 "F gas
½"M gas
½"M gas
)
200 (100 cm
2
14.7
13.5
214
270
70 - 75
70 - 75
VEA1,5 - VEC3
345x245
355x245
307x245x345
-
Movable - flat
1359
980
559
587
533
572
218 – 242
183
Chapter Fire prevention safety
390
390
TermoNICOLETTA
Forno - DSA
1
16.6
13.5
10.5
3
3.9
81,1
0.07
130
18.5
1 "F gas
½"M gas
)
200 (100 cm
)
2
2
14.7
214
70 - 75
VEA1,5 - VEC3
345x245
307x318x345
330x300x370
1423
587
572
254
390
); unfavourable type
3