Maintenance
Storage
For storing the rechargeable shears select a dry place out of the reach of children and insure
that this area is free of frost in the winter.
Cleaning
• Clean the cutter head with a dry cloth after each trimming.
• The drive should be cleaned and lubricated at the end of the gardening season (see „change
cutting blades").
ttention!
• Under no circumstances should you activate the switch while cleaning the device (figure B3,
position 2).
• Drive repairs may only be carried out by a WOLF service facility!
Change Cutter *
1. Remove wheels (figure W1)
Carefully pull the wheels apart until they come off the rechargeable shears. Then remove the
wheels from below.
2. Remove skid (figure W2)
Lever the retainer (1) upwards and then remove the skid from the rear (2).
3. Replace cutting head (figure W3/W4/W5/W6)
Remove the cutting head from the rechargeable shears. Lubricate the plastic ring of the cutter
with the lubrication tube**(W3) provided, clean the visible area of the drive, and lubricate
this as well with the lubricant provided. Turn the new cutter head with the plastic ring in the
direction of the drive.
Note for shear blades ( ccu 8 EM, ccu 10 EM):
Please ensure that the blades are staggered in relationship to each other.
Note for shrub blades ( ccu BS EM):
Position the plastic ring in such a way that it is precisely placed over the eccentric tappet (W4).
Push the blade diagonally under the projections (W5, 2) and position it in the recharageble
shears so that the drill holes of the blade (W6) sit above the bolts of the rechargeable shears.
4. Fastening the skid (figure W2)
Push the skid far enough over the rechargeable shears until the skid retainer snaps in place.
5. Positioning wheels (figure Z2)
See ccessories for description
*For replacement blades see accessories
**Part of the „replacement blade package"
Replace batteries
1. Remove cover (figure W7)
Place a coin in the cover slot and press in the direction of the blade (1). Remove the cover
from above (2).
2. Replace batteries (figure W8)
Remove both plugs from the batteries (3); remove the batteries from the shears. Place the
new batteries in the shears and connect the two plugs.
3. Fastening the cover (figure W2)
Push the lid with the projection (4) under the edge of the shears and then press the cover on
the shears (5).
Note: Please ensure that no cable protrudes from the shears when fastening the cover!
13