LED indicator / Beeper
1
► 1. LED indicator
LED indicator / Beeper on the tool shows the following functions.
Function
Auto-stop with fastening
completion
Alarm against insuffi-
cient fastening
Alarm for low battery
capacity
Auto-stop with low
remaining battery
capacity
Check of the LED indi-
cator, light and beeper
operation
Anti-reset of controller
Overheat protection
Detection of switch
trigger operation when
installing battery
Motor failure detection
Double-hitting detection
Maintenance alarm
Alarm for unavailable data
communication (with the
tool in connection with PC)
Indication that data commu-
nication is available (with the
tool in connection with PC)
Status of the tool
The preset fastening
Lights up in green for
torque has been achieved
approximately one
and the tool has stopped.
second.
The preset fastening torque
Lights up in red.
has not been achieved,
because the switch trigger
has released before com-
pleting the fastening.
The battery power became
Flickers in red slowly.
low and it is time to replace
the battery cartridge.
The battery power is
Lights up in red.
almost used up and the
tool stopped.
When the battery car-
Lights up first in green,
tridge is installed, the tool
next red.
checks for its LED indica-
(And then the light
tor, light and beeper.
comes on.)
The battery voltage dropped
Flickers in red and green
abnormally for some reason,
alternatively.
and the tool stopped.
Tool's controller heated
Flickers in red quickly.
up abnormally and the
tool stopped.
When the battery car-
Flickers in red and green
tridge is installed with
alternatively.
the switch trigger pulled,
the tool stops to avoid
unintentional start.
Motor failure has been
Flickers in red and green
detected. At this time,
alternatively.
tool does not work.
When the operator
Lights up in red.
starts to re-fasten an
already-fastened screw,
the tool detect it and stops.
A maintenance time has
Flickers in yellow.
come according to your pre-
set number of screws driven.
Data cannot be exchanged
Flickers in yellow.
between the tool and PC in
spite of the connection.
The tool is connected to
Flickers in green.
PC and data communi-
cation is available.
Status of the LED indicator/beeper
LED indicator
A long beep
A series of long beeps
A long beep
A series of very short
beeps
A series of short beeps
A series of short beeps
A series of short beeps
A series of short beeps
A long beep
7 ENGLISH
Action to be taken
Beeper
–
Retighten the screw.
Replace the battery with
fully charged one.
Replace the battery with
fully charged one.
Replace the battery with
fully charged one.
Remove the battery car-
tridge immediately and
cool the tool down.
Release the switch
trigger.
Ask your local Makita
Service Center for repair.
–
Reset the alarm with the
application software.
–
Restart the application
software and re-connect
the USB cable.
–
–
–
–
–