Installation Of The Indoor Unit - Daikin FTXK09P Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The indoor unit must be installed in such a way so as to
prevent short circuit of the cool discharged air with the hot
return air. Please follow the installation clearance shown in
the fi gure. Do not place the indoor unit where there could
be direct sunlight shining on it. Also, this location must be
suitable for piping and drainage, and be away from doors
or windows.
Air fl ow
(Indoor)
min. 2" (50)
Required space
(Space for
maintenance)
CAUTION
• Must be mounted with the lowest moving parts atleast
8ft (2.4m) above fl oor or grade level.
Connect the drain hose to the outlet pipe of indoor unit.
Bind the joint with tape.
Outlet
pipe

INSTALLATION OF THE INDOOR UNIT

min. 2" (50)
(Space for
maintenance)
Drain hose
Outlet pipe
Tape
(Field supply)
Drain hose
The refrigerant piping can be routed to the unit in a number
of ways (left or right from the back of the unit), by using
the cut-out holes on the casing of the unit. Bend the pipes
carefully to the required position in order to align it with
the holes. For the side and bottom out, hold the bottom of
the piping and then position it to the required direction. The
condensation drain hose can be taped to the pipes.
Right-side, right-back or right-bottom piping
Right-side piping
Remove pipe port cover
here for right-side piping
Remove pipe port cover here
for right-bottom piping
Left-side, left-back or left-bottom piping
Remove pipe port cover here
for left-bottom piping
1-10
Right-back piping
Bind coolant pipe
Right-bottom
and drain hose
piping
together with
insulating tape.
Remove pipe port cover
here for left-side piping
Left-side piping
Left-back piping
Left-bottom piping

Publicité

Table des Matières
loading

Table des Matières