Télécharger Imprimer la page

Glatz M 8 Instructions De Montage page 5

Publicité

Les langues disponibles

Les langues disponibles

Bodenhülse "M8"
Ground socket mod. "M8"
Douille de sol mod. "M8"
Piantone da interrare "M8"
1.9
Adjustment of the ground socket
Determine the direction in which the sunshade pole is to be tilted based on the
prevailing situation and align the ground socket as shown in the above diagram. The
tilt hinge must be secured opposite a set of three holes.
The direction of the sunshade can be selected irrespective of the installation of the
ground socket.
1.10
Setting example
a) Align the flange ring in a perfect horizontal position
position
b) Loose covering up to 10 cm depth
permissible
c) Concrete layer BH PC 250
d) Mesh reinforcement K 188 top and bottom
e) PVC sheet as wetness barrier
f) Filter gravel 0/30 compacted
h) Hard foam collar to cover the thread
k) Pipes and cables for motor drive or
incorporated ligtning
1.11
Foundation dimensions
Sunshade width x length x
2
up to 10 m
70
x
2
up to 15 m
80
x
2
up to 20 m
100
x
*from 1000m sea level 50 cm are recommended because of the frost depth.
1.12
Other possibilities of placing
 Mounting plate
 Mounting plate special for isolated grounds
 Movable base
10.2005-DEFI
Direction for tipping
the shade mast
height
70
x 40 cm*
80
x 40 cm*
100
x 40 cm*
Sunshade width x length x height
2
up to 25 m
120
x
2
up to 30 m
125
x
2
up to 40 m
135
x
2
up to 50 m
150
x
120
x 40 cm*
125
x 40 cm*
135
x 40 cm*
150
x 40 cm*
5

Publicité

loading