damages.
Make sure that power supply voltage corresponds to the values appearing on the rating
plate of the refrigerator. Consider also that the maximum allowable power voltage variation is
+/-6%.
IMPORTANT: THE REFRIGERATOR MUST BE PROPERLY EARTHED. The manufacturer disclaims all
responsibility for damage resulting from non-observance of this safety principle. If the refrigerator
must be installed far from the power point, make certain that the connection complies with the
standards in force.
THE MANUFACTURER DISCLAIMS ALL RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY
DAMAGE ARISING FROM INCORRECT INSTALLATION.
6. TECHNICAL SPECIFICATIONS
The built-in electrical installation is composed of control and safety devices adequately lodged in
the cabinet. The relevant wiring diagrams and part lists are contained in a sealed plastic envelo-
pe together with the present booklet. Keep such documents with the booklet. The technical data,
which are also reported on the rating plate inside the showcase (see fig. 11 on page 18), are shown
in table III, page 18.
THE SOUND LEVEL GENERATED BY THE RUNNING REFRIGERATOR IS BELOW
70 DB(A). THE REFRIGERATOR GENERATES NO HARMFUL VIBRATIONS.
Thermostat adjustment is reserved for the technical after-sales service only.
7. LOADING PRODUCTS
Switch the cabinet on by the wall cutoff switch. As soon as the cabinet is on it will start its cooling
cycle. Allow about two hours before loading any products, which must already be at their preserva-
tion temperature. THE CABINET IS FACTORY-REGULATED FOR THE ANTICIPATED PERFORMANCE.
When loading products make certain that:
• they are similar in size and type;
• the load limit line is not exceeded and products do not hamper correct cool air circulation (see
fig. 16, page 21).
8. USE
DUALIO showcases were designed and manufactured exclusively for the display of prepacked fresh
food like sausages, dairy produce, delicatessen, pre-packed food and meat, dried pastry and pre-
cooked food a (class 3M2, 3M1, 3M0).
Their purpose is to keep food temperature, not to bring it down. Therefore, when introduced, THE
FOODSTUFFS MUST ALREADY BE AT THEIR CONSERVATION TEMPERATURE. Do not load foods that
have undergone heating.
For best cabinet operation we recommend:
• loading the products as explained in the preceding section;
DEFROSTING
The number and duration of defrosts are factory-set.
The user must never alter their adjustment.
The cases are supplied as including a U-trap for their connection to the sewer system (WHICH