3.10. Resetting the Overheat Protectors of
the Heater and the Water Reservoir
See figure 11. If the temperature of the sauna room
becomes dangerously high, the overheat protector
(1) will permanently cut off the supply of the heater.
The overheating protector (1) can be reset after
the heater has cooled down. Please check that the
stones are piled properly and the sensor is installed
according the installation instructions. See also the
installation instructions for control unit.
If water reservoir empties during the use, the
overheat protector (2) cuts off the steamer power.
The overheating protector (2) can be reset after the
steamer has cooled down.
The reset button is located under the heater.
Figure 10.
Replacing the Heating Elements
1
Figure 11.
Resetting the Overheat Protectors of the Heater and the Water Reservoir
EN
1
2
13