Open the primary and secondary air control.
After having started the fire with small pieces of wood and waited until it is well lit.
Bring the flue gas control to the oven position.
Close any butterfly valve placed on the flue gas exhaust pipe must also be opened.
The control regulation during the LIGHTING phase is the following :
VICENZA EVO
VERONA
How to set the machine to BOIL WATER (VERONA)
• Keep the smokes control on the cooker function – HOTPLATE USE pos. B
• Primary air completely open.
• Secondary air completely open.
• Load wood as described in the manual (hourly load).
How to set the machine to COOK BISCUITS (VERONA)
• Primary air register completely open
• Secondary air register completely open.
• Bring the smokes control to the cooker function – LIGHTING USE position. This keeps the oven temperature stable around 230 °C.
• Load wood as described in the manual (hourly load).
• Wait for 230 °C to be reached.
• Place the tray of biscuits in the low position for 25-30 minutes (slow cooking) or in the medium position for 15-20 minutes (quick cooking).
• Turn the tray halfway through cooking, if necessary.

TECHNICAL DATA

Definition in accordance with
Nominal power in kW
Efficiency in %
Assorbimento elettrico in W
Smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Chimney draught in Pa (mm H
Hourly wood consumption in kg / h
CO measured at 13% oxygen in %
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances
heatable m
3
(30 kcal/h x m
(*) The proposed value are indicative. The installation must, in any case, be sized and verified according to the general calculation method in UNI
EN13384-1 or by another method of proven efficiency.
(**) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of the
product is: favourable type of building (30 kcal/h x m
x m
3
).
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating, in
the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
The declared technical data have been achieved by burning beech wood class "A1" according to the requirement UNI EN ISO 17225-5 and wood
moisture content less than 20%. By burning a different kind of wood the efficiency of the product itself could change and some specific adjustments
on the appliance could be needed.
1A - PRIMARY air
OPEN
OPEN
O)
2
(wood with 20% humidity)
3
)
3
); less favourable type of building (40 kcal/h x m
2A - SECONDARY air
OPEN
OPEN
Picture
6.
VICENZA EVO
EN 12815
6
25
86
120
10 ( 1,0 mm H
1,7
0,059 - 732 mg/m
6,1
164
225 x 160
220 x 147 x 337
350 x 175 x 410
850-910
600
600
131
172 (*)
ENGLISH
B - SMOKES control
LIGHTING USE function
LIGHTING USE function
VERONA
EN 12815
(**) 4 - 200 x 200 Ø 200
O)
10 ( 1,0 mm H
2
0,05 - 633 mg/m
3
225 x 160
220 x 147 x 337
430 x 320 x 430
Movable - flat
850-910
Chapter FIRE SAFETY
229 (*)
3
); unfavourable type of building (50 kcal/h
8
25
78,4
150
O)
2
2,4
3
11,8
208
800
600
161
25