Once setting the DIP switches, turn on the main power switch and press button A-2.
Wait until the cycle LED light (A-5) turns off and release the button A-2. The new cycle
parameters are saved. You may change the cycle parameters during the programming
phase using the DIP switches or return DIP switches in the original condition. After
having set the parameters wait approx. 1 second and turn of the main power. The
appliance increases the number of cycles at each new cycle and when the number is
reached the A-5 LED blinks; you can stop this alarm only by starting the regeneration
cycle.
Detergent injector in the tank
The appliance is ready to be equipped with a detergent injector through a hole
with a diameter of 8.5 on the back side of the tan. We do not recommend to add
other holes and if it is necessary to remove the external panels before drilling.