An efficient protective earth system in conformity with the current regulations
guarantees the safety of the appliance and its operator.
This point must be checked and if any doubt, have the entire electric system checked by
the professionally qualified technician who made the connexion to the electric mains.
No liability for injury or damage to persons, animals or property will be accepted by the
manufacturer because of defective earth system.
Connect the appliance directly to a wall plug socket. The use of adaptors, multiple
sockets and/or extensions is not recommended.
All wiring connections for this appliance must be made in accordance with the wiring
diagrams furnished on the appliance. The appliance must be connected to an
equipotential system, in accordance with European regulations in force. Connect the
appliance using the clamp with the symbol
terminal conform to a 10 mm 2 sections following the norm CEI 64.8. Connexion to
electric mains must be done using a multipolar magneto thermic differential switch with
contacts opening of 3mm or more. To choose the kind and dimensions of the main cable
bear in mind the distance between the appliance and the power point, the installed
power indicated on the ratings plate (C3) and the mains voltage. The cross section of
the cables must not be less than 2.5mm2. Use a H07RN-F cable if the power cable
needs to be replaced connecting it to the terminal box and clamp it .Avoid any strain on
the power supply cable. Check high limit thermostat of the tank F-B3 if the model allows
it by pushing the manual re setting button. The operating temperature of the warm is
factory set to de 85°C. It can be changed with the previous screw of the thermostat F-
B1.
4. Accessories
The appliance can be fitted with retrofit accessories later that are available upon
request:
•
peristaltic detergent dispenser;
•
peristaltic rinse-aid dispenser;
•
drain pump;
•
rinse pump;
Models with water softener must be ordered directly at the factory.
Maintenance of the peristaltic dispensers: how to replace the internal tube
1)
Gently remove the transparent cover;
2)
To remove it, place both the roller cases vertically;
3)
Remove the coupling on the left side of the pump by pulling the tube upwards
and following its full length, then turn the roller case clockwise until the
coupling on the right side of the pump can be extracted;
4)
Place the roller case on horizontal position;
5)
push down the coupling on the left of the pump, with the curved part facing the
bottom;
(C9) rear the appliance and using a
27