Télécharger Imprimer la page

Casselin CLVAD Mode D'emploi page 28

Masquer les pouces Voir aussi pour CLVAD:

Publicité

Les langues disponibles

Les langues disponibles

6)
Press the tube into its seat, gradually along its full length, and manually turn
the roller case clockwise until the right-hand coupling is also inserted
correctly;
7)
Fix the protective cover. Place the dispenser in the appropriate seat.
Use the regulation screw (Fig H): turn it clockwise or anti-clockwise the product
quantity is increased or decreased. The dosing times go from 1 to 25 seconds.
"A0.2g" of rinse-aid corresponds to 2cm in the transparent feed tube (cross-section
4x7mm). The dispensers must never be used when empty or allowed to become
empty. Read the unit "Peristaltic dispensers" in the section "use" to fill the
dispenser and the dispenser tank connection tube.
Safety instructions and user training
The skilled personnel performing the installation and the electric connections are
requested to instruct the user about the functions of the appliance and the safety
indications to respect.
A practical demonstration of how to use the appliance must be performed to the final
user and the written instructions for use must be given to the user.
5. Programming of the cycles in regeneration mode
The DIP switches on the card are used to enter the regeneration cycles (when the set
parameter is reached the LED lights up). We recommend setting the regeneration as
first phase and then setting the other DIP switches as wanted. If regulation isn't done the
card will no count the cycles.
How to proceed:
It must be done when the appliance is off, disconnected from the main power and with
the door opened.
Set the DIP switches to choose the number or cycles for the regeneration alarm.
See table:
28

Publicité

Chapitres

loading

Ce manuel est également adapté pour:

ClvadpvClvadpvad