3. Terminal Connection Method
Please pay extra attention to the wiring. Incorrect connection may cause damage the power supply.
 When connecting input, output wiring, and CN201, input AC-Line should be OFF.
 The output load line and input line shall be separated to improve noise immunity.
 The protective earth (PE) must be connected to the
 Remote sensing lines shall be twisted or use shielded wires.
 Remote ON/OFF control lines shall be twisted or use shielded wire.
 Current for each terminal screw shall be 40A or less.
 Basic Connection (Local Sensing)
Connect with the attached connector to CN201
 ON/OFF control required
"CNT-" terminal is ground for "CNT+" terminal.
terminal.
 DCOK output signal required
Open collector method shown below shall be used
"COM" terminal is ground for "DCOK" terminal.
 PV control required
Inject external voltage between 3~6V
"COM" terminal is ground for "PV" terminal.