UK
WESTFIRE · WF32
Only specific SE models are suitable for smoke control areas, alterations should not be attempted.
Westfire smoke control stoves should not be burnt with the door left open.
The refuelling procedure : - allow the newly charged fuel to burn with the secondary air control set at maximum
for up 3 to 4 minutes. After this period, with flames from the logs fully established, close the secondary air supply
to the low output setting. When operating at high output (secondary air set fully open) the new refuel charge
does not require any boost air to establish combustion.
RE-FUELLING WHEN BURNING WOOD
BURNING WOOD IN A SMOKE CONTROL AREA
To re-fuel your stove in the cleanest way only refuel your stove when flames have died down and you have
glowing embers. Before refuelling, open air controls fully and slide. Unlatch door to equalise pressure with the
room. Open door gently, add one piece of wood WESTFIRE UNIQ32 and close the door. Once the flames from the
logs are fully established move air control to nominal position. The stove is only suitable for intermittent use only:
do not run overnight or for long periods unattended.
Experience will determine the settings that produce best results. Use a flue thermostat to check the stove is not
overheating. Flue thermostats should be placed directly above collar of the stove on a non insulated section of
pipe. (efficient operating temperature range is between 200c and 400c?)
Stove
Log length & weight
WF32
4 pieces approx 22 cm, 2.1 kg
SE MODELS – smoke exemption modification
Smoke exempt models are factory fitted with a air stop on the air control slider:
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can
occur. Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel
charge will ignite in a reasonable period. If there are too few embers in the fire bed, add suitable kindling to
prevent excessive smoke.
Operation with door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance
door left open except as directed in the instructions.
Dampers left open
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not be
operated with air controls, appliance dampers or door left open except as directed in the instructions.
Fuel Overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess
smoke.
Annual service
The inside of the stove should be serviced /cleaned once a year. To clean the inside, remove all ash, soot and tar
residue from the combustion chamber. Remove insulated chamber panels and baffle, to clean out any dirt and
soot will collected behind them. Check the quality of all insulated panels and replace any which are damaged or
cracked, replace stove door rope cord in the door. Check glass is correctly positioned.
The stove, the flue pipe connection and the chimney should be checked regularly by a qualified engineer. The
chimney should also be checked for blockages before relighting the stove if it has not been used for an extended
period of time.
19