UK
Typical installation of an inset stove
Distance to Combustible materials
Combustible materials should not be located where the heat dissipating through the walls of fireplaces or flues
could ignite it. Therefore when installing the stove in the presence of combustible materials due account must
be taken of the guidance on the separation of combustible material given in Building Regulations Approved
Document J and also in these stove instructions.
Distance to combustible materials rear
Distance to combustible materials side
Distance to soft furnishing in front
The minimum distances to flammable materials are specified on the EN 13240 plate on the back of the stove.
WESTFIRE · WF32
Vermiculite back fill insulation
Multi-fuel liner
Existing clay liner
Register plate
Supporting lintel
Adapter to appliance
(supplied by flue supplier)
Non combustible housing
Minimum height 450 mm for
glass floor plate 12 mm thick
Glass floor plate
12
WF32 / UNIQ32
300 mm
200 mm