Release and lift off the upper part for free access to the filter. Lift the filter straight up. If appropriate, fit a plastic bag over the
cyclone to prevent the dust in the filter from spreading. Check the gasket when replacing the filter. A worn gasket can allow
hazardous dust to escape. Never use old gaskets or non-OEM parts. Place used filters in a plastic bag and seal the bag. See
instructions below.
1
Motor
The typical service life of a fan motor's original brushes is 600-700 hours. The brush can be replaced. The service life of the
second brush set is approx. 400 hours, while that of the third set is approx. 300 hours. After this time, the motor is considered
worn out and should be replaced.
Regular checks
Regularly check the power cord for damage.
The machine must be tested and inspected at least once a year due to its use with hazardous materials. Worn parts must be
replaced. Never risk functionality and service life. Only use genuine parts.
Consumables
Description
Plastic bag, standard
Plastic bag Longopac 12m
Plastic bag Longopac 23m
Fine filter, cellulose with integrated filter guard
Fine filter, polyester with integrated filter guard
HEPA filter
For spare parts, see the
Dustcontrol
Warranty
The warranty period is two years and covers manufacturing defects. The warranty is valid on condition that the machine is used in
the normal way and receives the required service. Normal wear and tear is not covered. Repairs must be carried out by
Dustcontrol or personnnel authorized by Dustcontrol. Otherwise, the warranty is void.
Troubleshooting
Problem
Motor not running.
Motor stops immediately after starting.
Motor runs, but no suction.
18
2
3
Part No.
42291
44763
432177
42029
42028
42027
website.
Cause
Power supply not connected.
Incorrect fuse.
Suction hose not connected.
DC 2900, Art.nr. 94164-G
4
Action
Connect power supply.
Replace with correct fuse.
Connect hose.