Dimensions
When Installing Above an Oven
■ The appliance may only be installed over a Panasonic oven.
■ Allow for extra spaces for air circulation as shown below.
Side View with an Oven
Oven
Dimensions of Countertop Cutout
Building rear wall
Min.51
Building side wall
Min. 59
44
EN-
(measurement: mm)
Oven
Min. 60
Flow of intake
and exhaust
Min.51
R3 1
Min.51
870
3
0
Countertop front
Building side wall
Electrical Work
WARNING
Electrical work must be performed by a legally qualified electrician.
Electrical Requirements
■
This appliance must be supplied with the proper voltage and frequency, and
connected to an individual, properly earthed branch circuit, protected by a
circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)
■
This appliance is not fitted with other means for disconnection from the supply
Min. 60
mains having a contact separation in all poles that provide full disconnection
under overvoltage category III conditions. Means for disconnection must be
incorporated in the fixed wiring in accordance with the wiring rules.
■
Single-phase A.C. 220-240 V, 50 Hz electrical system must be used. (It is also
possible to use a three-phase electrical system.) If connecting to aluminium
wiring, use connectors approved for use with aluminium wiring.
■
Check with the local utilities for electrical codes applied in the area. Failure to
wire the appliance according to governing codes may result in a hazardous
condition.
■
After installation, show the customer where the breaker for the appliance is
located.
Installation of the Earth Leakage Circuit Breaker
■
In accordance with the electrical wiring rules, incorporate the earth leakage
circuit breaker in the home electrical wire.
■
Follow the specification of the earth leakage circuit breaker as follows.
Rated current: 50 A*, rated sensitivity current: 30 mA
* If rated current is 40 A, please change to 7200 W under "Power Management"
in settings. (See page 11)
45
EN-