Electrical Work
WARNING
Electrical work must be performed by a legally qualified electrician.
Electrical Requirements
This appliance must be supplied with the proper voltage and frequency, and
■
connected to an individual, properly earthed branch circuit, protected by a circuit
breaker or fuse. (The rating plate is on the bottom of the appliance.)
This appliance is not fitted with other means for disconnection from the supply
■
mains having a contact separation in all poles that provide full disconnection
under overvoltage category III conditions. Means for disconnection must be
incorporated in the fixed wiring in accordance with the wiring rules.
Single-phase A.C. 220-240 V, 40 A, 50 Hz electrical system must be used.
■
(It is also possible to use a three-phase electrical system.) If connecting to
aluminium wiring, use connectors approved for use with aluminium wiring.
Check with the local utilities for electrical codes applied in the area. Failure to
■
wire the appliance according to governing codes may result in a hazardous
condition.
After installation, show the customer where the breaker for the appliance is
■
located.
Installation of the Earth Leakage Circuit Breaker
In accordance with the electrical wiring rules, incorporate the earth
■
leakage circuit breaker in the home electrical wire.
Follow the specification of the earth leakage circuit breaker as follows.
■
Rated current: 40 A, rated sensitivity current: 30 mA