Please note: that the Aduro 9-7 must be installed on a floor with the adequate load-bearing capacity. If the existing
construction does not meet this requirement, appropriate adaptation measures must be taken (e.g. a load-
distributing plate).
If the wood burning stove is to be placed close to flammable material, such as a wooden floor or carpet, it must be
placed on a non-flammable base. The floor plate should extend for at least 30 cm in front of the wood burning
stove, and 15 cm on each side.
2.2 Pipe connection
Aduro 9-7 leaves the factory with the flue outlet mounted on the top. If you require the flue outlet on the back, use a
90 flue pipe. This flue pipe should be shortened, see illustration below. The top outlet is finished with the plate that
lies in the ash drawer. A flue pipe with an internal diameter of 150 mm should be used for Aduro stoves.
2.3 Connection to a brick chimney
If the stove is being connected to a brick chimney, a curved flue pipe should be used via the top outlet. After
measurement, a hole is made in the chimney in which the pipe sleeve is placed and fireplace mortar is used to seal
it in place. The stove is placed in position and the flue pipe is put in place. A thin gasket is placed between the flue
pipe and the pipe sleeve to seal the joints. The flue pipe should protrude 5–10 cm into the pipe sleeve, but must not
block the opening in the chimney (see the illustration below).
X
The wood burning stove can be connected to a chimney to which other heat sources are connected.