6. Set up

F1
F2
F3
F4 [EBZ6500RH]
F5 [EBZ6500RH]
US-8
■ BLOWER
1. Connect the blower and pipe with flexible hose.
Clamp both ends of the flexible hose securely
with the hardware supplied with the unit. (F1)
2. Align the protrusion and the groove provided on
the tube ends and twist the tube until
connection is locked up. (F2)
3. Apply grease to the pipes if necessary.
(1) Flexible hose (2) Pipe, swivel
(3) Clamp (4) Pipe, straight
(5) Pipe, end (6) Grip assy [EBZ6500]
NOTE
A light lubricant may be used to ease assembly
of flexible pipe to blower elbow.
■ GRIP
• The position of the Grip can be adjustable back
and forth by loosening "knob bolts" on Grip by
hand. (F3)
(1) Knob bolt
■ THROTTLE LEVER
[EBZ6500RH]
• Set up the clamp to the swivel and tighten the
screw on the clamp.
(1) Clamp
(2) Swivel
(3) Screw
■ THROTTLE CABLE
[EBZ6500RH]
• Use the clamp to fasten the colgate tube
containing the throttle cable and the power
cable to the hose.
(1) Clamp
(2) Cable
(3) Hose