Stiebel Eltron ETW 120 Notice D'utilisation Et De Montage page 23

Masquer les pouces Voir aussi pour ETW 120:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

B2
R1
X20
X23
A2
X25
X17
X16
V4
X14 - X15
X11
X12
A1
X13
R1
B1
TA
N
LE` LH
LH`
LE
+ -
X3
1
DC
Aufladesteuerung
Kleinspannungs-System
Wiring diagram
A1
Elektronic charge regulator
A4
Operating panel electronics
Brick sensor-charge (at 20 ºC ≈ 541 Ω)
B1
E1-E6 Heater element
F1
Safety thermal cut-out
F2
Microfuse (250V 2A slow)
K1
Thermal relays
M1-M2 Blower fan
N4
Protective temperature regulator - charge
N5
Protective temperature regulator -
discharge
R1
Adjustor - charge 10 kΩ (Selector switch)
V4
Control lamps fornormal and emergency
operation
X1
Main connection terminals
X2
Terminal
X3
DC-Terminal (0,9 - 1,43 V)
X16 Control signal adapter, 4-stage
X17 Output reducer, 4-stage
A4
1
R2
L
S2
5
N4
X21
X22
K1
4
N
1
X2
L-
A1
N
N
N
N
L
SH
Z1
AC
Aufladesteuerung
230 V-System
E5
E3
E1
M3
M2
M1
F2
N5
3
2
A2
L
LE
3
2
N
Z2
1/N/PE
230V
Special accessories
(does not form part of the scope of supply at
installation, mark the invidual special accessory with
a cross in each case)
RTI-E3
A2
Elektronic discharge regulator
B2
Room temperature sensor - discharge
(at 20 ºC ≈ 27,1 kΩ)
R2
Adjustor - discharge 10 kΩ
S2
ON/OFF-switch for room temperature
sensor
X25 Internal connection lead A1-A2
Supplementary heating
E8
Supplementary heating element
N2
Temperatur regulator Supplementary heating
N3
Temperatur regulator Supplementary heating
S1
ON/OFF-switch for Supplementary heating
When assembling supplementary heating (E8)
observe the switching capacity.
E6
vi
E4
E2
ws
br
L3
L2
L1
F1
L3
L2
L1
K1
X1
1
L3
L2
L1
3/N/PE
400 V
RTI-EP2
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Etw 180Etw 240Etw 300Etw 360Etw 420Etw 480

Table des Matières