InsTaLLaTIon GuIdes
InsTaLLaTIon InFoRMaTIon
Installation must be carried out in
accordance with national standards.
The fixture must only be used when
complete with safety screen. If the
screen is damaged or broken, the fixture
must not be used. Restore the original
conditions before reusing.
The fixture is installed under CL II
protection standards, particular care
must be taken while assembling to
ensure that exposed metal parts do not
come into electrical contact with parts of
the electrical installation connected to
a protection conductor. This light fixture
must be installed only for the use for
which it was designed, namely for the
illumination of outdoor spaces.
Any other use must be considered to
be improper and dangerous, and the
manufacturer cannot be held liable for
any damage caused by improper and
unreasonable use.
asseMBLY
Installation of the light fixture
Separate the G3/4 connection from the
luminaire (Fig. 1) and secure it, screwing
it to the support using the rear part of the
wrench provided (Fig. 2). Extract at least
50 cm of power cable from the support
(Fig. 3) and insert it into the luminaire
(still closed) (Fig. 4). IMPORTANT! Insert
the cable taking care to perforate the
membrane of the cable grommet. Once
inserted, pull it back out a short way so
that the membrane wraps back around it,
ensuring correct insulation against water
(Fig. 5). Direct the light fixture correctly
with respect to the road (Fig. 6). Secure
the luminaire to the support by means
of the G3/4 connection using the wrench
provided. Tightening the small grub screw
on the side of the connection to a force of
6Nm prevents involuntary rotation of the
luminaire (Fig. 7).
Once the light fixture is mounted, unscrew
the two M6 size screws on the front using
an Allen key (Fig. 8) (no element separates
from the body during installation) and
open the luminaire, allowing the lower
frame to swing (Fig. 9.). Secure the power
cable to the body using the predisposed
cable tie (Fig. 10) and connect it to the
disconnecting switch (Fig. 11) (cut the
cable if it is too long). Re-close the
luminaire with an Allen key, applying a
force of 2.5Nm (Fig. 12).
MaInTenance
Replacing the cabling plate
Maintenance can be carried out on the
light fixture while it is still installed
on the support. Unscrew the two M6
screws on the front with an Allen key (no
element separates from the body during
maintenance) and open the luminaire,
leaving the lower frame to swing (Fig.
9), this way the disconnect switch will
remove voltage to the electrical auxiliaries
automatically. To remove the cabling
plate, simply disconnect the power cables
(Fig. 13), disconnect the terminal block
that goes to the bulb from the cabling
plate (Fig. 14), unscrew and remove the
bulb following the instructions indicated
on the piece (Fig. 15-16). Loosen the two
screws that secure the cabling plate to
the lens (Fig. 17). Slide out and remove
the entire plate (Fig. 18-19).
PHoToBIoLoGIcaL RIsK
The luminaire should be positioned so
that prolonged staring into the luminaire
at a distance closer than 2,38m [9 1/4ft].
en
neri.biz
15