A. supplied seal
B. supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
Technical information
Hob dimensions
Width
Depth
Other technical data
TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:
Bypass diameters
BURNER
Triple Crown
26
A
B
Gas original:
Gas replacement:
230 V ~ 50 Hz
II2E+3+ (BE)
I2E (LU)
R 1/2"
3
56
Kitchen unit with door
A
60 mm
B
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and the
oven must be installed separately for safety
reasons and to let easy remove oven from the
unit.
744 mm
510 mm
G20/G25 (2E+) 20/25 mbar (BE) = 12 kW
G20 (2E) 20 mbar (LU) = 12 kW
G30 (3+) 28-30 mbar = 858 g/h
G31 (3+) 37 mbar = 843 g/h
Ø BYPASS 1/100 mm
30 mm
min 20 mm
(max 150 mm)
www.zanussi.com