produces a good deal of smoke and odour, it is therefore important that the first time you light your stove the room
should be well ventilated. During the process it is important to open and close the stove door periodically (every
30mins) during the first couple of firings therefore preventing the door seal cord around the door from sticking and
coming away from the door. Once the Heat-resistant paint has hardened; the stove door must be kept closed except
when lighting the stove, adding firewood or removing ash in order to prevent flue gas from escaping.
Lighting your appliance
Quality Firelighters should be used when lighting the stove. (Never use mentholated spirit, petrol or other flam-
mable liquids). Lighting your stove with fire lighters will be more reliable and easier than paper.
To light your stove
1. Place a few smaller pieces of dry wood (kindling) in the stove on top of the non toxic firelighters.
2. Fully pull open the air slider (Secondary air) and air slider (Primary air) it maybe necessary pull the ash pan
drawer open 1cm as well)
3. Light the firelighters close the door.
4. Once the fire has caught, add two pieces of wood measuring approx 22cm with a combined weight of approx
1.6kg and close the door.
5. After approximately 1.5 minutes when the fire is burning brightly shut the primary air control under the ash pan.
6. After approximately another 3 minutes close the secondary air slider by 50%, for the stove to burn cleanly
plenty of secondary air is needed, do not be tempted to shut the fire down too early as this may cause smoke. At
nominal heat output, expect to refuel your stove approximately once an hour.
WF 33 and WF 34 are all equipped with a control valve for secondary air designed to ensure a plentiful supply of
oxygen during firing. When lit, the stove will get very hot and due care must therefore be exercised. Please use a
glove when operating levers and dampers.
RE-FUELING
To re-fuel in the cleanest way. Before refuelling open secondary air slider fully, also open primary air slider fully and
leave for 5 minutes. Open door gently, add two pieces of wood measuring approx 22cm with a combined weight of
approx 1.6kg and close the door. Leave the air sliders open for 10 minutes to allow the fire to reach a good tempera-
ture. Then close primary air slider and slide secondary air value to 50% open.
In the event of a chimney fire: Close the air damper and the stove door, and call 999 or your local fire department.
WESTFIRE · WF33 WF34
Tertiary air ports: six ports at the rear of the combus-
tion chamber provide fresh preheated air to improve
secondary combustion of gases
Door handle, pull out right away from fire.
Wear protective glove when fire is lit.
Ash pan: when lighting open primary air slider (under
the ash pan) and pull open the ash pan by 1cm.
11