The Westfire UNIQ 33, 34 wood burning stove is lined with heat deflection panels and baffles, these panels are
designed to ensure the maximum efficiency and are an integral part of the clean burn process of the stove. These
baffles should not be removed apart from for cleaning the stove. Any defective panels should be replaced.
Connection to chimney
Westfire UNIQ 33, 34 wood stove has both rear and top flue connector that allows connection to either a masonry
chimney or a prefabricated factory made insulated metal chimney in accordance with the instructions for "Connec-
tion to chimney" given in the instruction booklet.
Commissioning and handover
Ensure loose parts are fitted in accordance with the instructions, page 13. 'Vermiculite fire brick installation se-
quence' before handover. Operation of primary and secondary air controls must be fully explained.
On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, when
a small fire may be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and
emitted safely to atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left
with the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be
used on the stove and warn them to use only the recommended fuels for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to
use a fireguard to BS EN 8423:2002 in the presence of children, aged and/or infirm persons.
Operating your stove – UNIQ 33, 34
WARNING; CO Alarm
Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm sounds unexpectedly,
follow the instructions given under "Warning Note" above.
Use a fireguard in the presence of children, and old and/or infirm people. The fireguard should be manufactured
in accordance with BS 8423:2002, Fireguards for use with solid fuel appliances.
Initial lighting
The heat-resistant paint on your stove will cure and harden the first time you light your appliance. The curing process
WESTFIRE · WF33 WF34
10
Top flue exit 150 mm
Distance from rear to centre of flue
UNIQ 33 & 34:
130 mm
Rear flue exit 150 mm
Height to centre of rear flue
UNIQ 33:
910 mm
UNIQ 34:
1065 mm
Closed combustion air intake 100 mm
Height to centre of air intake
UNIQ 33:
70 mm
UNIQ 34:
80 mm