Westfire WF UNIQ 15 Notice D'installation Et D'utilisation page 17

Table des Matières

Publicité

VERMICULITE FIRE BRICK INSTALLATION SEQUENCE – WESTFIRE UNIQ 15
Installation procedure:
1 –
Inner Top Baffle Brick
2 –
Rear Brick
3 –
Base Grate
4 –
Metal Spacer
5 –
Right Base Brick
6 –
Left Base Brick
7 –
Right Angled Side Brick
8 –
Right Side Brick
9 –
Left Angled Side Brick
10 – Left Side Brick
11 – Outer Top Baffle Brick
Inner top baffle brick 1 – positioned on
secondary air pipe & between two retaining
lugs on rear panel.
Inner top baffle brick 1 – positioned on
secondary air pipe & between two retaining
lugs on rear panel.
Rear brick 2 fitted in line with tertiary
air holes.
Base grate 3 fitted between base bricks.
Metal spacer 4 positioned in front of
grate 3.
Right base brick 5 fitted.
Left base brick 6 fitted.
WESTFIRE · WF15 WF16
1.
11.
2.
9.
3.
10.
6.
5.
4.
17
7.
8.
Right angled side brick 7 fitted.
Right side brick 8 fitted.
Left angled side brick 9 fitted.
Left side brick 10 fitted.
Outer top baffle brick 11 ( smallest
straight edge resting on top edge of rear
brick) fitted and supported with two
side pins.
UK

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wf uniq 16

Table des Matières