UK
There are no European rules regarding the minimum distance to non-flammable walls, Westfire recommend leav-
ing a gap of at least 10 cm behind and to sides of stove.
Soapstone base and top Plates for the UNIQ 16
When installing a UNIQ 16 with Soapstone top plates remove standard louvre grill top plate from stove.
Place soapstone panels directly on top of stove and fit new rear grill to rear. If top flue exit is not used a cover
plate is supplied on the stove to cover flue area.
UNIQ 16 soapstone plates
Height with 10 cm plate
Height with 20 cm plate
Height with 30 cm plate
Base soapstone
When installing a Uniq 16 with a base soapstone a 12mm floor plate or construction hearth is still to be installed
in accordance with document J regulations.
UNIQ 15,16
Westfire Insulated chambers
The Westfire UNIQ 15, 16 wood burning stove is lined with heat deflection panels and baffles, these panels are
designed to ensure the maximum efficiency and are an integral part of the clean burn process of the stove. These
baffles should not be removed apart from for cleaning the stove. Any defective panels should be replaced.
Connection to chimney
Westfire UNIQ 15, 16 wood stove has both rear and top flue connector that allows connection to either a masonry
chimney or a prefabricated factory made insulated metal chimney in accordance with the instructions for "Connec-
tion to chimney" given in the instruction booklet.
WESTFIRE · WF15 WF16
Top flue exit 125 mm internal/150 mm external
Distance from rear to centre of flue
UNIQ 15:
UNIQ 16:
Rear flue exit 125 mm internal/150 mm external
Height to centre of rear flue
UNIQ 15, 16:
Closed combustion air intake 100 mm
Height to centre of air intake
UNIQ 15, 16:
10
UNIQ 16
1160 mm
1260 mm
1360 mm
60 mm
155 mm
180 mm
960 mm
110 mm