Operation with door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance
door left open except as directed in the instructions.
Dampers left open
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not be
operated with air controls, appliance dampers or door left open except as directed in the instructions.
Fuel Overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess
smoke.
Annual service
The inside of the stove should be serviced /cleaned once a year. To clean the inside, remove all ash, soot and tar
residue from the combustion chamber. Remove insulated chamber panels and baffle, dirt and soot will collect
behind it and this must be cleaned out. Insulated panels may crack if hit too hard by a piece of firewood. This has no
effect on the function of the stove (this is not the case with the smoke plate). The Insulated panels will only need to
be replaced once they become very worn and are no longer whole, or if they crack in several places. Check glass is
correctly positioned, replace stove door rope cord in the door. Check glass is correctly positioned.
The stove, the flue pipe connection and the chimney should be checked regularly by a qualified engineer. The
chimney should also be checked for blockages before relighting the stove if it has not been used for an extended
period of time.
The paint/ lacquer can wear thin in exposed places due to overheating. This, and other lacquer damage, may be
repaired using a Westfire Senotherm paint/lacquer spray available from your Westfire dealer.
Ash must be stored in a non-combustible container and must not be mixed with other combustible waste.
TROUBLE SHOOTING, CHECK THE FOLLOWING:
1.
Fire Will Not Burn – check
a)
the air inlet is not obstructed in any way,
b)
that chimneys and flueways are clear,
c)
that a suitable fuel is being used,
d)
that there is an adequate air supply into the room,
e)
that an extractor fan is not fitted in the same room as the fire.
2.
Fire Blazing Out Of Control – check
a)
the doors are tightly closed,
b)
the air control is turned down to the minimum setting,
c)
the air inlet damper is closed and that it is not prevented from closing completely by a piece of ash,
d)
a suitable fuel is being used,
e)
the door seals are in good condition.
f)
the chimney draft may be too strong
g)
check ash pan seal and
h)
check for ash below ash pan causing pan to not seat correctly and clean out.
3.
Soot forms on the window
a)
The firewood may be too wet
b)
the intake of secondary air may be insufficient
c)
fire not hot enough
4.
The stove fails to heat fully
a)
The firewood may be too wet
b)
the intake of secondary air may be insufficient
WESTFIRE · WF 44 · WF 45 · WF 46