Lenze 8200 motec E82MV551_4B Instructions De Montage page 135

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1)
Keypad
PC
LU
c
11
OC1
a
12
OC2
a
13
OC3
a
14
OC4
a
15
OC5
a
16
OC6
a
50
OH
a
OH
e
OH
e
EDK82MV222 DE/EN/FR 11.0
Troubleshooting and fault elimination
Fault
Cause
DC−bus
Mains voltage is too low
undervoltage
Voltage in DC−bus
connection is too low
400 V controller is
connected to 240 V mains
Short circuit
Short circuit
Capacitive charging current
of the motor cable is too
high
Earth fault
A motor phase has earth
contact
Capacitive charging current
of the motor cable is too
high
Controller
Set acceleration time is too
overload during
short (C0012)
acceleration or
Defective motor cable
short circuit
Interturn fault in the motor
Controller
Set deceleration time is too
overload during
short (C0013)
deceleration
Controller
Frequent and too long
overload during
overload periods
steady−state
operation
Motor overload
Motor is thermally
2
(I
x t overload)
overloaded by e.g.
l
impermissible
continuous current
l
frequent or too long
acceleration processes
Heatsink
Ambient temperature is too
temperature >
high
+85 °C
Heatsink
Heatsink is very dirty
temperature >
+80 °C
Heatsink
Impermissible high currents
temperature >
or frequent and too long
+80 °C
acceleration processes
l
Fault messages
Remedy
Check mains voltage
Check power supply module
Connect controller to correct
mains voltage
l
Search for cause of short
circuit; check motor cable
l
Check brake resistor and
cable to brake resistor
Use shorter/low−capacitance
motor cable
Check motor; check motor cable
Use shorter/low−capacitance
motor cable
Deactivate earth−fault detection
for test purposes
l
Increase acceleration time
l
Check drive dimensioning
Check wiring
Check motor
l
Increase deceleration time
l
Check dimensioning of the
external brake resistor
Check drive dimensioning
l
Check drive dimensioning
l
Check setting of C0120
Allow controller to cool and
provide for better ventilation
Clean heatsink
l
Check drive dimensioning
l
Check load, replace
rough−running, defective
bearings, if necessary
8
135

Publicité

Table des Matières
loading

Table des Matières