Lenze 8200 motec E82MV551_4B Instructions De Montage page 119

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Code
No.
Name
C0002
Parameter
*
set manage−
s
ment
uSEr
Restoring
the delivery
status
C0002
Transferring
*
parameter
s
sets with the
keypad
uSEr
(Cont.)
EDK82MV222 DE/EN/FR 11.0
Possible settings
Lenze Selection
0
0
Ready
Lenze setting ð PAR1
1
Lenze setting ð PAR2
2
Lenze setting ð PAR3
3
Lenze setting ð PAR4
4
Lenze setting ð FPAR1
31
Lenze setting ð PAR1 + FPAR1
61
Lenze setting ð PAR2 + FPAR1
62
Lenze setting ð PAR3 + FPAR1
63
Lenze setting ð PAR4 + FPAR1
64
Keypad ð controller
70
with function module application
I/O, INTERBUS, PROFIBUS−DP,
LECOM−B, DeviceNet, CANopen
10
with all other function modules
l
Commissioning
Important controller codes
IMPORTANT
PAR1 ... PAR4:
l
Parameter sets of the
controller
l
PAR1 ... PAR4 also contain
the parameters for the
function modules
standard I/O, application
I/O, AS interface, system
bus (CAN)
FPAR1:
l
Module−specific
parameter set of the
fieldbus function modules
INTERBUS, PROFIBUS−DP,
LECOM−B,
DeviceNet/CANopen
l
FPAR1 is saved in the
function module
Restore the delivery status in
the parameter set selected
Restore the delivery status in
the fieldbus function module
Restore the delivery status in
the selected parameter set of
the controller and in the
fieldbus function module
By means of the keypad you
can transfer the parameter
sets to other controllers.
During the transmission the
access to the parameters via
other channels is inhibited!
Overwrite all available
parameter sets (PAR1 ... PAR4,
if required FPAR1) with the
corresponding data of the
keypad
7
119