C1
Phase
page 5
Only for version with external exhaust (suction): if required by the selected height (H1), it is possible to install the hood using only the trellis (T1)
and the flue (G).
• Attach the extension supporting elements (SP) to the trellis (T1) using the 8 self-threading screws (V4) through the pre-drilled holes (Fig.
• Mark 4 drilling points on the ceiling (also identified on page 3), drill (Fig.
porting elements (SP) to the ceiling by the relative screws (V1) (Fig.
With false ceilings, the extension supporting elements (SP) must always be bolted to the false ceiling: said false ceiling must be reinforced
or somehow fitted with a solution that can guarantee safely attaching the hood to it, taking into account the strength of the used materi-
als and the weight of the hood (reported on page. 2).
The fixing kit (screws and plugs) supplied with the hood can only be used on masonry walls: should it be necessary to install the
hood onto walls in a different material, assess other fixing systems keeping the wall resistance and weight of the hood in mind (indicated
on page 2).
EXTERNAL EXHAUST HOOD VERSION (SUCTION)
• If you wish, install the check valve (M)(Phase
as illustrated in the figures (Fig.
• Find the best length for the flexible (recommended) or rigid pipe to discharge the fumes and connect it suitably to the connection (Phase
page 5).
HOOD VERSION WITH INTERNAL RECIRCULATION (FILTERING)
• Ensure that the active carbon filters are assembled onto the hood, if not, install them as indicated in the instructions
• If installed, remove the connection (ERM) and any check valve (M) installed on the hood's air outlet fitting (perform, in reverse order, the opera-
tion described in the instructions
INSTALLATION ON CEILING
INSTALLATION ON CEILING WITH FALSE CEILING
INSTALLATION ON CEILING WITHOUT EXTENSION (H) AND TRELLIS (T)
F
Phase
page 6
• Insert the extension (H) into the flue (G) and secure them together with masking tape.
• With external exhaust (suction) versions, it is possible to insert extension (H) with the slots facing downwards so that they are not visible when
the installation height allows it.
G1
Phase
page 6 (only for installations on ceiling WITHOUT false ceiling)
• Raise the assembly (H+G) until it is touching the ceiling (Fig.
• Attach the assembly (H+G) to the trellis (T) with 4 screws (V3) without tightening them all the way (Fig.
G2
Phase
page 6 (only for installations on ceiling WITH false ceiling)
Attach the extension supporting elements (SP) to the trellis (T) with 8 self-threading screws (V4) being sure to press it up against the false ceiling
1
Fig.
).
• Raise the assembly (H+G) until it is touching the false ceiling (Fig.
• Attach the assembly (H+G) to the extension supporting elements (SP) with 4 screws (V3) without tightening them all the way (Fig.
H
Phase
page 7
• Raise the hood so that it is near the trellis that is already attached to the ceiling (Fig.
• Centre the 4 metric screws, (V5) that are pre-screwed onto the trellis, (T1) (Fig.
the 4 metric screws definitively (V5) (Fig.
I
Phase
page 7
• Remove the masking tape that was temporarily holding the flue (G) and extension (H) (Fig.
• Take out the 4 screws (V3) that attach the extension (H) to the trellis (T) (Fig.
2B
(Fig.
) and slide the extension (H) downwards (Fig.
• By lowering the extension (H) it is possible to connect the pipe (F) to the external discharge pipe (with the suction version)(Fig.
• Set up the electric connection only once the electric power supply has been cut off.
L
Phase
page 7
• When the electrical connection is set up, as well as the discharge connection, raise the extension (H) (Fig.
2A
) or, with false ceilings, to the extension supporting elements (SP) (Fig.
• Attach the flue (G) to the hood by 2 self-threading screws (V6) (Fig.
INSTALLATION ON CEILING WITHOUT EXTENSION (H) AND TRELLIS (T)
M
Phase
page 8
• Attach the flue (G) to the hood by 2 self-threading screws (V6) (Fig.
N
Phase
page 8
• Raise the hood towards the trellis (Fig.
• Set up the connection with the external discharge pipe and the electrical connection, performing the latter after disconnecting the electrical
power supply.
• Centre the 4 metric screws, (V5) that are pre-screwed onto the trellis, (T1) (Fig.
the 4 metric screws definitively (V5) (Fig.
D
page 5); if the connection is installed (ERM) take it down (Fig.
2
3
4
5
-
-
-
) and put the previously removed connection back in (ERM) (Fig.
D
page 5).
F
G1
H
I
L
-
-
-
-
Phases
F
Phases
1
2B
).
3
). Keep the removed (V3) screws.
1
).
2B
).
2
) Put in 4 x ø 8mm expansion bolts and secure the extension sup-
3
).
G2
H
I
L
-
-
-
-
M
N
Phases
-
).
2
).
1
).
2A
) on the holes on the hood; shift the hood sideways and tighten
1
)
2A
) or, with false ceilings, to the extension supporting elements (SP)
2B
) by the 4 screws (V3).
3
).
1
).
2A
) on the holes on the hood; shift the hood sideways and tighten
21
1
), install the check valve (M)
6
).
Q
on page 9.
2
).
3
).
4
).
1
) and re-attach it to the trellis (T) (Fig.
1
)
E