Binding the underfloor heating controller without time program – continued
Binding room setpoint generators/sensors HCW82/
HCF82 with the underfloor heating controller
Setting the underfloor heating
controller to the binding mode
Press and hold the installation
1
button
controller for 2 seconds.
The
LED lights up. The LED
of zone 1 flashes green.
Binding
Press the installation button
2
underfloor heating controller again until
the red LED of the desired zone flashes.
Press the bind button at
3
the HCW82/HCF82.
The HCW82 transmits the room
setpoint temperature (offset) and the
measured room temperature. The HCF82
transmits only the room temperature
to the underfloor heating controller.
The LED of the selected zone at
the underfloor heating controller
lights continuously red.
!
The course is the same at the
HCW82 and HCF82, however
only the room temperature
is transferred at HCF82.
3
1 2 3
+
Connecting devices (binding)
on the underfloor heating
at the
-
Binding the room temperature selector T87RF
with the underfloor heating controller
Setting the underfloor heating
controller to the binding mode
Press and hold the installation
1
button
controller for 2 seconds.
The LED
of zone 1 flashes green.
Binding
Keep the left-hand field below the display
2
pressed for approx. 10 seconds.
bo flashes.
Turn the upper part clockwise
3
until Hc is displayed.
Press the left-hand field below the display
4
briefly.
flashes several times.
The LED of the selected zone at
the underfloor heating controller
lights continuously red.
2
10 SECONDS
on the underfloor heating
lights up. The LED