Binding room setpoint generators/sensors with the evohome controller –
continued
Binding the underfloor heating controller
with the evohome controller
Press and hold the installation
1
button
controller for 2 seconds.
The LED lights up. The LED
of zone 1 flashes green.
Press the green connection button
2
at the evohome controller.
If binding was successful, the
orange LED of the underfloor
heating controller lights up.
Binding of the zone (room) is completed.
Repeat the process to bind further zones:
• Press the bind button
controller twice (skip red flashing LED).
The green LED of the first zone flashes green.