Molift EvoSling / www.etac.com
General
Declaration of conformity
The Molift EvoSling Shadow and related acces-
sories described in this operator manual are CE
marked in accordance with EU Council Directive
MDR (EU) 2017/745 concerning medical devices,
class 1, and has been tested and approved
by a third party according to standard EN ISO
Conditions for Use: Lift and transfer of a person will always pose
a certain risk and only trained personnel are allowed to use the
equipment and accessories covered by this user manual.
Warranty: 2-year warranty against defects in workmanship and
materials of our products. For Terms and conditions,
see www.etac.com
Visit www.etac.com for download of documentation to
ensure you have the latest version.
Important
This User Manual contains important safety instructions
and information regarding the use of the sling and acces-
sories. In this manual the user is the person being lifted.
The assistant is the person operating the lifter.
This symbol indicates important information
related to safety. Follow these instructions
carefully.
Read User Manual before use!
It is important to fully understand the con-
tent of the user manual before attempting
to use the equipment. Read the manual for
both lift and sling
General Safety Precautions: Molift EvoSling Shadow is designed
for use with a 2-point suspension but also works with a 4-point
suspension. Only use accessories and slings that are adjusted to fit
the user, type of disability, size, weight and type of transfer. It is
important that the sling has been tested with the individual user
and for the intended lifting situation. Make a decision on whether
one or more assistants are required. Plan the lifting operation
in advance to ensure that it is as safe and smooth as possible.
Remember to work ergonomically.
Assess the risk and take notes.
You as the assistant are responsible for the safety of the user!
Molift slings shall only be used to lift persons.
Never use the sling to lift or move objects of
any kind.
If maximum load (SWL) differs between lifter,
suspension and body support unit, then the low-
est maximum load shall always be used
The sling should not be stored in direct
sunlight.
Labels and symbols
Molift EvoSling
1
EvoSling HighBack Net Padded
300
660
2
3
YYYY-MM-DD
Barcode according to GS1-128
(01)xxxxxxxxxxxxxx(11)xxxxxx(21)xxxxxxxx
(01):GTIN number (11):Date (21):Serial number
4
5
Symbols:
Manufacturer
Date of manufacture.
YYYY-MM-DD
(year/month/date)
YYYY-MM-DD
CE marked
Refer to user manual
This way up, this side is outside
255
560
Max user weight
Medical Device
About EvoSling Shadow
Etac supplies a wide selection of slings for different types of
transfers. Molift EvoSling Shadow is suitable for users that
require total support. The sling has no straps or seams on the
surface that is supposed to be in contact with the user, therefore
it can be left under the user after transfer into sitting position.
EvoSling Shadow is especially suitable for users in moulded seat
units. The sling has a high back, headsupport and it supports
the entire core. It has split leg support with a medium opening.
EvoSling Shadow is not suitable for double leg amputees. The
slings can be used for lifting from a lying or sitting position to a
sitting or lying position. Approved for users with weight up to
300kg. Molift EvoSling Shadow is avalable in sizes XXS –XL, in
Net polyester. See the combination list for the correct sling and
suspension combination.
Productlabel
Lifting strap /
Leg strap
4
1. Main label
2. Size label
3. Batch and serial number label w.
GS1-128 barcode.
4. Product label
5. Periodic inspection label/ Name tag
Wash symbols:
Slings can be washed at
temperatures ranging
176
from 60 up to 85º C
Tumble drying,
max 60º C.
Do not iron
Do not dry clean
Do not bleach
Upper
Lifting strap
Middle
Lifting strap