WARNING:
▶ Do not use the unit if you think it may be
frozen, as this could result in serious
damage to the unit. Wait until you are
sure it has completely thawed out
before you switch it on.
WARNING:
Before turning on power, open cold water
shutoff valve to the unit and turn on all hot
water taps supplied by the unit. Flow water
out the tap(s) until all air has purged from
the unit and plumbing.
5.1
Sink
▶ Check that the power is switched on at the circuit breaker
panel.
▶ Turn on the hot tap FULLY.
If you do not turn the tap full on, you will find that the
temperature of the water may vary. The hot water can be
adjusted by altering the temperature dial and correctly
setting the flow rate. Refer to appendix on page 14 - correct
flow vs. temperature.
If the unit has been used recently:
▶ run the water through for a few seconds to let the
temperature settle down.
If the unit has been used recently, You may initially get a
short burst of very hot water from the unit.
If a second tap connected to the unit is also turned on, the hot
water will be shared between the two, therefore the flow and/
or the temperature of the water will decrease.
5.2
Adjusting the flow
▶ Ensure the service valves are open and check that no pipe
joints leak.
▶ Turn on the hot tap fully at the sink.
▶ Adjust the outlet service valve till the water comes out of
the tap at the recommended flow rate for the required
temperature. Refer to Appendix on page 12: Correct flow
vs. Temperature.
If the required temperature is different from the factory
setting, turn the Adjustment Spindle (Fig. 7 ) until the
outlet temperature is correct.
▶ Check that the unit works correctly when the sink tap is
closed and then opened again; if not adjust the service
valve slightly.
▶ The outlet shut off valve can be used to regulate
temperature or flow of water from the unit.
Tronic 3000 C Pro
Starting up the Tronic 3000C Pro | 11
When using the hot water at a fixture, open
tap fully. To regulate hot water temperature,
adjust the temperature dial and flow rate as
recommended in the Appendix on page 10.
NOTICE:
If the unit is servicing a single lever faucet
you may need to restrict the cold water
supply to the faucet to balance water
pressure and improve performance.
NOTICE:
▶ Before leaving the site, the installer
should demonstrate the unit to the user
and give him/her this guide.
▶ Remove nameplate in direction of Arrow A (Fig. 7 ).
▶ Adjust the temperature setting using a screwdriver on the
spindle as shown by arrow B (Fig. 7 ).
Fig. 7
Temperature adjustment spindle
▶ Replace the nameplate.
6 720 647 088 (2017/05)